Loading...
HomeMy WebLinkAbout910 RANDOLPH ST UNIT 2INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/21/2025 11/25/2025 2026-00000020 $250.00 Customer #: 24033 IA INVESTMENT PROPERTY 5001 1ST AVE SE SUITE 105,221 CEDAR RAPIDS, IA 52402 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 910 RANDOLPH #2 - 10-1-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION FEE 3RD Total Price $250.00 CUSTOMER # 24033 BILLING DATE 10/21/2025 DUE DATE 11/25/2025 INVOICE 2026-00000020 CHARGES $250.00 Less Prepayment Total Due —> City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 910 Randolph St # 2 - 910 Randoplh ST, BLDG 910 Randolph St - STE Unit # 2, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 10101/2025 Lead Inspector BARRY STRATTON Inspection Type Rental Inspection t REINSPECTION Other Inspectors NIA ;q6a3 TA gnu Rope+ 425 E. 3rd Street Inspection Number 17042-R3 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 o Passed codes NEXT STEPS 0 9 Failed codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 SIGNATURES Contact signature ---C_-_frIA,L IA Investment Properties LLC CHECKLISTS Inspector signature 3-, Reinspection Date 10129/2025 10/01/2025 BARRY STRATTON 10/01/2025 GENERATED ON 10/1/25, 9:22 AM 1 OF 4 Reinspection Status Code Description Fail 1018.1- General. Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats, tables, furnishings, displays and similar fixtures or equipment. The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Fail 603.2 - Abatement of unsafe conditions and electrical Fail hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 906.1- Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Location: Front door is obstructed. Location: Outlet cover by front door broken. Outside light not in working condition. GENERATED ON 10/1/25, 9:22 AM 2 OF 4 Fail Fail Fail Fail Fail Fail 907.2.11- Single- and multiple -station smoke alarms. Listed single- and multiple -station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. 915.1.1 - Where required. Carbon monoxide detection shall be provided in Group 1-1, 1- 2, 1-4 and R occupancies and in classrooms in Group E occupancies in the locations specified in Section 915.2 where any of the conditions in Sections 915.1.2 through 915.1.6 exist. R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle shall have GFCI protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2) Location: Need smoke detectors installed in unit # 2. Location: CO Detector not working. Location: Deck balusters broken and need repaired. Deck stairs need repaired to meet code. Location: Kitchen floor needs replaced. Kitchen ceiling needs repaired. Wall around door, molding around door, and door threshold need repaired. Install new threshold on entrance door to # 2. Obstruction at front door. Location: Stove not in working condition. Location: Switch/outlet covers GENERATED ON 10/1/25, 9:22 AM 3 OF 4 ro FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid NIA $250.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 10/1/25, 9:22 AM 4 OF 4