Loading...
HomeMy WebLinkAbout1306 W DONALD ST BLDG 200INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/21/2025 11/25/2025 2026-00000024 $50.00 Customer #: 22009 WATERLOO AFFORDABLE HOUSING 740 S 75TH ST OMAHA, NE 68114 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1306 W DONALD BLDG 200 - 9-24-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION FEE 1ST Total Price $50.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22009 10/21/2025 11/25/2025 2026-00000024 $50.00 Less Prepayment Total Due —+ City of Waterloo $0.00 $50.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 1306 W Donald ST, Waterloo IA 50703 INSPECT AILS Inspection Date 09/24/2025 Lead Inspector BARRY STRATTON Inspection Type Rental Inspection l REINSPECTION 0.93),L6/3 aktc103SLI \oat , -31" T-eb 5 � 425 E. 3rd Street �* � Other Inspectors N/A Inspection Number 17508-R1 Shift Station Unit N/A NIA NIA SUMMARY OF INSPECTION 0 0 Passed codes NEXT STEPS 0 23 Failed codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 GENERAL NOTES BARRY STRATTON - 09/24/2025 @ 10:15 Structure is unfit for occupancy. Tenants shall be removed until building can be brought up to code. SIGNATURES Contact signature Inspector signature Darlissa CHECKLISTS Reinspection Date 10/22/2025 09124/2025 BARRY STRATTON 09124/2025 GENERATED ON 9/24/25, 10:24 AM 1 OF 6 Reinspection 5ta«ss co.., Description Fait Fail Fail Fail 1010.2 - Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. 1018.1 - General. Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats, tables, furnishings, displays and similar fixtures or equipment. The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. 1031.1 - General. Emergency escape and rescue openings shall comply with the requirements of this section. 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 703.1 - Maintaining protection. Materials and firestop systems used to protect membrane and through penetrations in fire -resistance -rated construction and construction installed to resist the passage of smoke shall be maintained. The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Missing electrical covers, open panels, hanging light fixtures Location: Open walls and ceilings GENERATED ON 9/24/25, 10:24 AM 2 OF 6 Fail Fail Fail Fail 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 705.2 - Inspection and maintenance. Opening protectives in fire -resistance -rated assemblies shall be inspected and maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and draft control doors shall not be modified. 907.2.11 - Single- and multiple -station smoke alarms. Listed single- and multiple -station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. 907.2.11.1 - Group R-1. Single- or multiple -station smoke alarms shall be installed in all of the following locations in Group R-1: 1.In sleeping areas. 2.In every room in the path of the means of egress from the sleeping area to the door leading from the sleeping unit. 3.In each story within the sleeping unit, including basements. For sleeping units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. GENERATED ON 9/24/25, 10:24 AM 3 OF 6 Fail 907.2.11.2 - Groups R-2, R-3, R-4 and 1-1. Single- or multiple -station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of occupant load at all of the following locations: 1.On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2.In each room used for sleeping purposes. 3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. Fail 907.2.11.5 - Interconnection. Where more than one smoke alarm is required to be installed within an individual dwelling unit or sleeping unit in Group R or 1-1 occupancies, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Fail Fail 907.2.11.6 - Power source. In new construction, required smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms with integral strobes that are not equipped with battery back-up shall be connected to an emergency electrical system in accordance with Section 1203. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection. Exception: Smoke alarms are not required to be equipped with battery backup where they are connected to an emergency electrical system that complies with Section 603. R1- Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Fail R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Fail R3 - Unfit for Human Occupancy Is the structure found to be fit for human occupancy according to the code? (IPMC 108.1.3) Fail R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Location: Fire separation, fire barriers, fire walls Location: Fire ratings Location: Building unsafe to occupy in current condition. GENERATED ON 9/24/25, 10:24 AM 4 OF 6 Fail Fail Fail Fail Fail Fail R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle shall have GFCI protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2) R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, Teaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) Location: 1st floor common areas and apartments fore walls opened up 3-4 ft from floor. Water damaged plates and framing studs. Fire separation, Fire and smoke protection not being meet in current condition. Comments: Building shall be vacated until building meets fire code regulations for occupancy. Location: Fire separation and electrical issues Location: All pluming fixtures shall be installed and maintained in operable condition. GENERATED ON 9/24/25, 10:24 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $50.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 9/24/25, 10:24 AM 6 OF 6