Loading...
HomeMy WebLinkAbout1306 W DONALD ST BLD 300INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/21/2025 11/25/2025 2026-00000023 $50.00 Customer #: 22009 WATERLOO AFFORDABLE HOUSING 740 S 75TH ST OMAHA, NE 68114 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1306 W DONALD BUILD. 300- 9-24-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION FEE 1ST Total Price $50.00 CUSTOMER # 22009 BILLING DATE 10/21/2025 DUE DATE 11/25/2025 INVOICE # 2026-00000023 CHARGES $50.00 Less Prepayment Total Due —> City of Waterloo $0.00 $50.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 'asp ction Report BLDG 300 11306 W Donald ST, Waterloo IA 50703 INSPECTION D TAILS Inspection Date 09/24/2025 Lead Inspector BARRY STRATTON Inspection Type Rental Inspection REINSPECTION evb0 i :ord-)Lt 05 ()AL { 104 E. 3rd Street cil Other Inspectors N/A Inspection Number 17512-R1 Shift Station Unit NIA Station 3 NIA SUMMARY OF INSPECTION Go Passed codes NEXT STEPS 0 19 Failed codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 GENERAL NOTES BARRY STRATTON - 09/24I2025 @ 10:25 Structure unfit to occupy. SIGNATURES Contact signature ..rn\L Darlissa CHECKLISTS Reinspection Date 10/22/2025 Inspector signature 09/24/2025 BARRY STRATTON 09/24/2025 GENERATED ON 9/24/25, 10:26 AM 1 OF 5 Reinspection Cod Fail 1010.2 - Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Fail 1018.1 - General. Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats, tables, furnishings, displays and similar fixtures or equipment. The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Fail 1031.1 - General. Emergency escape and rescue openings shall comply with the requirements of this section. Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 703.1 - Maintaining protection. Materials and firestop systems used to protect membrane and through penetrations in fire -resistance -rated construction and construction installed to resist the passage of smoke shall be maintained. The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Fire walls and fire separation on common areas and apartments not up to code. Walls removed 3-4 ft up from floor. Plates and wall studs rotten from water damage. Location: Fire walls compromised by removal of drywall. Open penetrations in wall systems in common areas and apartments. GENERATED ON 9/24/25, 10:26 AM 2 OF 5 Fail Fail Fa.I Fail Fail Fai Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 705.2 - Inspection and maintenance. Opening protectives in fire -resistance -rated assemblies shall be inspected and maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and draft control doors shall not be modified. 907.2.11 - Single- and multiple -station smoke alarms. Listed single- and multiple -station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) R3 - Unfit for Human Occupancy Is the structure found to be fit for human occupancy according to the code? (IPMC 108.1.3) R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Location: Fire separation, fire walls, common areas. Location: Vacate building until such time repairs can be make to bring building up to code. GENERATED ON 9/24/25, 10:26 AM 3 OF 5 Fail R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Fail R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Fail R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) Fail R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Fail R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle shall have GFCI protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2) Fail R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) Location: Open fire walls and fire separation not being met Location: Mold, electric hazards, fire separation. GENERATED ON 9/24/25, 10:26 AM 4 OF 5 Elo FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid N/A $50.00 Invoice Number N/A Check Number Transaction Number N/A N/A GENERATED ON 9/24/25, 10:26 AM 5 OF 5