RENTAL INSPECTION - 1306 W DONALD BUILD. 300- 9-24-25
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION FEE 1ST
Total Price
$50.00
CUSTOMER #
22009
BILLING DATE
10/21/2025
DUE DATE
11/25/2025
INVOICE #
2026-00000023
CHARGES
$50.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$50.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
'asp ction Report
BLDG 300 11306 W Donald ST, Waterloo IA 50703
INSPECTION D TAILS
Inspection Date
09/24/2025
Lead Inspector
BARRY STRATTON
Inspection Type
Rental Inspection REINSPECTION
evb0 i :ord-)Lt 05 ()AL
{ 104 E. 3rd Street
cil
Other Inspectors
N/A
Inspection Number
17512-R1
Shift Station Unit
NIA Station 3 NIA
SUMMARY OF INSPECTION
Go
Passed codes
NEXT STEPS
0 19
Failed codes
Please direct questions about your Inspection to:
BARRY STRATTON
barry.stratton@waterloo-ia.org, 3199611280
GENERAL NOTES
BARRY STRATTON - 09/24I2025 @ 10:25
Structure unfit to occupy.
SIGNATURES
Contact signature
..rn\L
Darlissa
CHECKLISTS
Reinspection Date
10/22/2025
Inspector signature
09/24/2025 BARRY STRATTON 09/24/2025
GENERATED ON 9/24/25, 10:26 AM
1 OF 5
Reinspection
Cod
Fail 1010.2 - Door operations.
Except as specifically permitted by this section, egress doors
shall be readily openable from the egress side without the
use of a key or special knowledge or effort.
Fail 1018.1 - General.
Aisles and aisle accessways serving as a portion of the exit
access in the means of egress system shall comply with the
requirements of this section. Aisles or aisle accessways shall
be provided from all occupied portions of the exit access that
contain seats, tables, furnishings, displays and similar
fixtures or equipment. The minimum width or required
capacity of aisles shall be unobstructed. Exception:
Encroachments complying with Section 1005.7.
Fail 1031.1 - General.
Emergency escape and rescue openings shall comply with
the requirements of this section.
Fail 1032.2 - Reliability.
Required exit accesses, exits and exit discharges shall be
continuously maintained free from obstructions or
impediments to full instant use in the case of fire or other
emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
Fail 603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Fail 703.1 - Maintaining protection.
Materials and firestop systems used to protect membrane and
through penetrations in fire -resistance -rated construction and
construction installed to resist the passage of smoke shall be
maintained. The materials and firestop systems shall be
securely attached to or bonded to the construction being
penetrated with no openings visible through or into the cavity
of the construction. Where the system design number is
known, the system shall be inspected to the listing criteria
and manufacturer's installation instructions.
Description
Location: Fire walls and fire separation on common areas and
apartments not up to code. Walls removed 3-4 ft up from floor. Plates
and wall studs rotten from water damage.
Location: Fire walls compromised by removal of drywall. Open
penetrations in wall systems in common areas and apartments.
GENERATED ON 9/24/25, 10:26 AM
2 OF 5
Fail
Fail
Fa.I
Fail
Fail
Fai
Fail
704.1 - Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
705.2 - Inspection and maintenance.
Opening protectives in fire -resistance -rated assemblies shall
be inspected and maintained in accordance with NFPA 80.
Opening protectives in smoke barriers shall be inspected and
maintained in accordance with NFPA 80 and NFPA 105.
Openings in smoke partitions shall be inspected and
maintained in accordance with NFPA 105. Fire doors and
smoke and draft control doors shall not be blocked,
obstructed, or otherwise made inoperable. Fusible links shall
be replaced promptly whenever fused or damaged. Opening
protectives and smoke and draft control doors shall not be
modified.
907.2.11 - Single- and multiple -station smoke alarms.
Listed single- and multiple -station smoke alarms complying
with UL 217 shall be installed in accordance with Sections
907.2.11.1 through 907.2.11.7 and NFPA 72.
R1 - Unsafe Structures
Is the structure found to be dangerous to the life, health,
property or safety of either the public or occupants of the
structure? (IPMC 108.1.1)
R2 - Unsafe Equipment
Was the presence of unsafe equipment noted during the
inspection? Equipment may include boilers, heating
equipment, elevator, moving stairways, electrical wiring, and
flammable liquid containers. (IPMC 108.1.2)
R3 - Unfit for Human Occupancy
Is the structure found to be fit for human occupancy
according to the code? (IPMC 108.1.3)
R4 - Exterior Property Areas
Is the exterior property area maintained in a clean, safe, and
sanitary condition? This includes grading and drainage,
sidewalks and driveways, weeds, and pest infestations. (IPMC
302)
Location: Fire separation, fire walls, common areas.
Location: Vacate building until such time repairs can be make to
bring building up to code.
GENERATED ON 9/24/25, 10:26 AM
3 OF 5
Fail R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
Fail R6.A. - Interior Structure- Unsafe Conditions
Were any unsafe conditions noted during the interior
inspection?(IPMC 305.1.1)
Fail R6.B. - Residential Heating
Are dwellings provided with heating facilities capable of
maintaining a room temperature of 68F? (IPMC 602.2)
Fail R6.C. - Mechanical Eqiupment
Are mechanical appliances properly installed and maintained
in good working condition? (IPMC 603.1)
Fail R6.D. - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a GFCI. Every bathroom shall
contain not less than one receptacle. Any new bathroom
receptacle shall have GFCI protection. All receptacles shall
have the appropriate faceplate cover. (IPMC 605.2)
Fail R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Location: Open fire walls and fire separation not being met
Location: Mold, electric hazards, fire separation.