Loading...
HomeMy WebLinkAbout225 W PARKERINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/21/2025 11/25/2025 2026-00000022 $150.00 Customer #: 10461 LARRY NELSON PO BOX 2094 WATERLOO, IA 50704 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 225 W PARKER - 9-24-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION FEE 2ND Total Price $150.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10461 10/21/2025 11/25/2025 2026-00000022 $150.00 Less Prepayment Total Due —> City of Waterloo $0.00 $150.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 225 W Parker St - 225 W Parker ST, Waterloo IA 50703-2435 INSPECTION DETAILS Inspection Date 09/24/2025 Lead Inspector BARRY STRATTON Inspection Type Rental Inspection REINSPECTION )i)V qQ/lijdR) O' 1i-CqN \\Q59 425 E. 3rd Street Other Inspectors N/A Inspection Number 17307-R2 Shift Station Unit N/A N/A N/A SUMMARY OF INSPECTION 0 Passed codes NEXT STEPS 0 6 Faded codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 GENERAL NOTES BARRY STRATTON - 09/24/2025 @ 09:48 304.12: Handrail missing on back stairs. Reinspection Date 10/22/2025 BARRY STRATTON - 09/2412025 @ 09:48 305.6: Interior doors shall be maintained in good condition. Bathroom door needs replaced and bedrooms doors shall be capable of closing and opening. BARRY STRATTON - 09/24/2025 @ 09:48 605.1: Electrical service grounding cable in not attached to water service. Grounding wire just hanging on wall. SIGNATURES Contact signature Inspector signature LDN Properties LLC CHECKLISTS 09/24/2025 BARRY STRATTON 09124/2025 GENERATED ON 9/24/25, 9:50 AM 1 OF 4 Reinspection Status CcJz Fail 603.2 - Abatement of unsafe conditions and electrical Ohazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail Fail 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, 1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.1n Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-13:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group '- 1;1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. 907.2.11.5 - Interconnection. Where more than one smoke alarm is required to be installed within an individual dwelling unit or sleeping unit in Group R or 1-1 occupancies, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Description Location: Globes are needed on all light fixtures. Location: Fire Extinguisher is needed in unit. Location: Smoke detectors missing in bedrooms and in basement. All detectors need to be interconnected. GENERATED ON 9/24[25, 9:50 AM 2 OF 4 Fail Fail Fail R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) Location: Missing screens on windows, broken screens and broken window on front of house. Location: Kitchen sink not draining, sink cabinet base/floor rotten, Large Hole in bedroom wall needs repaired, bathroom door & hardware needs replaced, bathroom trim water damaged and wall/floor area growing mold. Back door needs replaced, Gap around door and threshold making door not weather tight. Water is getting into basement and standing water was present. Location: Toilet needs new hardware installed in tank. Water continues to run after flushing. Kitchen sink not draining. GENERATED ON 9/24/25, 9:50 AM 3 OF 4 ro FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid NIA $150.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 9/24/25, 9:50 AM 4 OF 4