COMMERCIAL INSPECTION - 3628 KIMBALL AVE - 7-2-25
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION 3
Total Price
$200.00
CUSTOMER #
24657
BILLING DATE
07/11/2025
DUE DATE
08/15/2025
INVOICE #
2026-00000036
CHARGES
Less Prepayment
Total Due —>
City of Waterloo
$200.00
$0.00
$200.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
R Smokes Plus - 3628 Kimball AVE, BLDG 3628 Kimball Ave, Waterloo IA 50701
INSPECTION DETAILS
Inspection Dater
07/02/2025
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (lYr) REINSPECTION
'a i1 (ij1
425 E. 3rd Street
Other Inspectors
NIA
Inspection Number
1138-R7
Shift Station Unit
N/A NIA N/A
SUMMARY OF INSPECTION
0 0
Passed codes
NEXT STEPS
0 2
Failed codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 06/1012025 @ 14:30
-Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 06/1012025 @ 14:30
Reinspection Date
07/2312025
If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections
& re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m.'** Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees
start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 06/10/2025 @ 14:30
re -inspection fee $150
BRAD BALDWIN - 06/10/2025 @ 14:30
annual inspection $80
BRAD BALDWIN - 06/10/2025 @ 14:30
Re -inspection fee $100. No progress
BRAD BALDWIN - 06/1012025 @ 14:30
Provide corrections to avoid progressive re -inspection fees, $150 next, and $200 for every inspection after.
BRAD BALDWIN - 06/10/2025 @ 14:30
Re -inspection fee $200
BRAD BALDWIN - 06110/2025 @ 14:30
No permits obtained at this time.
BRAD BALDWIN - 06/10/2025 @ 14:30
Permits were obtained so no fee this inspection, but if no progress made at next re-inspetion $200 re -inspection fees will resume.
BRAD BALDWIN - 06/10/2025 @ 14:30
GENERATED ON 7/2/25, 12:43 PM 1 OF 7
No re -inspection fee for today, but will resume at $200 at next re -inspection if ALL corrections not completed.
BRAD BALDWIN - 07/02/2025 @ 12:40
$200 re -inspection fee on 7/2/25. Provide corrections to avoid re -inspection fees.
SIGNATURES
Contact signature Inspector signature
Lafi Alagrabawi
CHECKLISTS
No signature
Report completed post inspection
_IM
Date: BRAD BALDWIN 07/02/2025
GENERATED ON 7/2/25, 12:43 PM 2 OF 7
Reinspection
Status Code
Description
GENERATED ON 7/2/25, 12:43 PM 3 OF 7
Fail
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
Comments: Obtain permits and inspections for all electrical and
building work completed without and any future work.
Additional comments: 7/2/25- Final building inspection still required,
permit holder shall contact Brian Wirtz to schedule. Electrical
inspection is complete
GENERATED ON 7/2/25, 12:43 PM
4 OF 7
5 OF 7
GENERATED ON 7/2/25, 12:43 PM
906.1 - Where required.
Portable fire extinguishers shall be installed in all of the
following locations: 1.In new and existing Group A, B, E, F, H,
I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group
R-2 occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C. 2.In Group E
occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C. 3. in storage areas of Group
S occupancies where forklift, powered industrial truck or
powered cart operators are the primary occupants, fixed
extinguishers, as specified in NFPA 10, shall not be required
where in accordance with all of the following: 3.1. Use of
vehicle -mounted extinguishers shall be approved by the fire
code official. 3.2. Each vehicle shall be equipped with a 10-
pound, 40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use. 3.3. Not less than
two spare extinguishers of equal or greater rating shall be
available on -site to replace a discharged extinguisher. 3.4.
Vehicle operators shall be trained in the proper operation, use
and inspection of extinguishers. 3.5. Inspections of vehicle -
mounted extinguishers shall be performed daily. 2.Within 30
feet (9144 mm) distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1; I-2, Condition 1; and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed. 4.On each floor of structures under
construction, except Group R-3 occupancies, in accordance
with Section 3316.1. 5.Where required by the sections
indicated in Table 906.1. 6.Special-hazard areas, including but
not limited to laboratories, computer rooms and generator
rooms, where required by the fire code official. Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
Location: Front and Back areas
Comments: Properly mount 2 2A 10BC currently serviced Fire
extinguishers 4" to5' above the floor in an accesible location . One in
front area and one in back area.
GENERATED ON 7/2/25, 12:43 PM
6 OF 7
Statement of Fees
FEE
Invoice Date Inspection Fee
N/A $200.00