Loading...
HomeMy WebLinkAbout428 FRANKLIN STINVOICE DATE DUE DATE "" INVOICE # TOTAL DUE 07/11/2025 08/15/2025 2026-00000039 $80.00 Customer #: 24548 XO FOOD & LIQUOR 428 FRANKLIN ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 428 FRANKLIN ST - 7-1-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24548 07/11/2025 08/15/2025 2026-00000039 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection R XO Food & Liquor - 428T, BLDG 428 Franklin St, Waterloo IA 50703 INSPECTION DETAILS Inspection Type Annual Inspection (1Yr) Lead Inspector BRAD BALDWIN Other Inspectors NIA 5L) g 425 E. 3rd Street Inspection Number 15645 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 47 Passed codes NEXT STEPS 0 8 Failed codes 0 21 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07/0212025 08:24 BRAD BALDWIN - 07/0212025 @ 08:24 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 07/2312025 BRAD BALDWIN - 07/02/2025 @ 08:24 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07/02/2025 @ 08:24 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Fahad Mpa CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 07/02/2025 GENERATED ON 7/2/25, 12:08 PM 1 OF 8 Emergency Equipment Status Code Fail O 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Description Location: Exit sign front entrance Comments: Repair or replace emergency lighting that failed to remain illuminated during testing GENERATED ON 7/2/25, 12:08 PM 2 OF 8 Additional Codes SatSoTed Code Fail Fail 2305.5 - Fire extinguishers. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill -pipe openings. 307.1 - General. A person shall not kindle or maintain or authorize to be kindled or maintained any open burning unless conducted and approved in accordance with Sections 307.1.1 through 307.5. Description Location: Outside mounted to exterior of building. Comments: If gas pumps are active to pump gas during hours the building is locked, fire extinguisher shall be properly mounted inside an approved cabinet within 75 ft of pumps. Tenant at time of inspection stated pumps are active to pump gas during hours that building is closed. Location: Near south wall coolers Comments: Remove incense candles burning during 7/1/25 immediately. GENERATED ON 7/2/25, 12:08 PM 3 OF 8 Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: Back storage Comments: Secure compressed gas cylinders with chain to avoid tip over. Chain shall be anchored to secure point, tanks currently chained to each other without anchor point. GENERATED ON 7/2/25, 12:08 PM 4 OF 8 Electrical Safety Status s Code Fail 603.2 - Abatement of unsafe conditions and electrical (x) hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail a 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Behind ATM machine Comments: Provide appropriate space between back of machine and electric plug to avoid pinching or damage to cord. Location: Box above upper alcohol area. Comments: Provide knockout plug for open hole in box. GENERATED ON 7/2/25, 12:08 PM 5 OF 8 Fail 0 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not Tess than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Kitchen Comments: Remove obstructions within 36" clearance in front of electric panel. GENERATED ON 7/2/25, 12:08 PM 6 OF 8 Commercial Cooking Hood Suppression System Code. Fail x 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSIIIKECA C10. 0n Location: Kitchen exhaust hood filters. Comments: Remove build up of grease on filters. Build up of grease also noted on electrical conduit and box behind fryer shall be corrected. GENERATED ON 7/2/25, 12:08 PM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 7/2/25, 12:08 PM 8 OF 8