Loading...
HomeMy WebLinkAbout1425 E SAN MARNAN AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/11/2025 08/15/2025 2026-00000032 $80.00 Customer #: 14982 LONGHORN STEAKHOUSE #5374 1425 E SAN MARNAN AV WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1425 E SAN MARNAN AVE - 7-7-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 14982 07/11/2025 08/15/2025 2026-00000032 $80.00 Less Prepayment Total Due City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Longhorn Steakhouse - 1425 E San Marnan DR, BLDG 1425 E San Marnan Dr, Waterloo IA 50702 INSPECTION DETAILS inspection Date 07/07/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E.3rd Street Inspection Number 14817 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 057 09 09 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07110/2025 @ 07:41 $80 annual inspection fee BRAD BALDWIN - 07/10/2025 @ 08:21 Fire extinguishers due serviced October 2025. BRAD BALDWIN - 07/10/2025 @ 08:39 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 08/0112025 BRAD BALDWIN - 07/1012025 @ 08:39 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07/10/2025 @ 08:39 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Caroline (2025) Mgr CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 07/10/2025 GENERATED ON 7/10/25, 8:41 AM 1 OF 5 Means of Egress Status Code Fail 1010.1.3 - Door opening force Forces to unlatch and open 0 doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment Status Cade Fail o 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fire Alarm System Status Cade Fail 2015 IFC - Fire alarm testing and maintenance Is the fire alarm system powered, operational and displaying normal operation (no troubles, supervisory, or alarms)? Description Location: Sprinkler riser room Comments: Repair or replace door to allow door to open with less than 15 Ibs of force. Replacement of door would require permit obtained with City Building Dept. Location: Rear kitchen exit door Comments: Remove boxes, kegs and all obstructions to clear path of egress to exit door. Description Location: Above hostess stand Comments: Repair or replace emergency lighting that failed to illuminate during testing. Description Location: Fire Alarm Comments: Provide correction and report to 1 deficiency remaining on Compliance Engine. GENERATED ON 7/10/25, 8:41 AM 2 OF 5 Fire Sprinkler System Status Code Fail Fail 5.2.1- Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor 903.3.3 - Obstructed locations. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Additional Codes Status Code Fail 606.3.1 - Ventilation system. The ventilation system in connection with hoods shall be operated at the required rate of air movement, and grease filters listed and labeled in accordance with UL 1046 shall be in place where equipment under a kitchen grease hood is used. Description Location: Sprinkler system Comments: Provide correction and report to 1 deficiency remaining on Compliance Engine. Location: Kitchen sprinklers Comments: Remove dust and all obstructions from sprinkler heads. Description Location: Kitchen exhaust hood filters Comments: Gap in hood filters shall be corrected. Filters shall be installed and maintained as manufactured. GENERATED ON 7/10/25, 8:41 AM 3 OF 5 Commercial Cooking Hood Suppression System Status Code Fail Fail 0 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Description Location: Near kitchen cooktop Comments: Remove grease build up behind cooktop on gas lines & electrical box. Location: Kitchen hood exhaust suppression system Comments: Provide service to hood suppression system, currently 80 days past due as of 7/10/25. Contractor shall upload service report to Compliance Engine. GENERATED ON 7/10/25, 8:41 AM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 7/10/25, 8:41 AM 5 OF 5