Loading...
HomeMy WebLinkAbout441 E TOWER PARK DRffff . •I I I 1 III. *... ` V INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/11/2025 08/15/2025 2026-00000030 $80.00 Customer #: 21369 CHILITO'S 441 E TOWER PARK DR WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 441 E TOWER PARK DR - 7-8-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 21369 07/11/2025 08/15/2025 2026-00000030 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. a) 69 Waterloo Fire Rescue Inspection Report Chilitos Mexican Bar - 441 E Tower Park DR, BLDG 441 E Tower Park Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 07/08/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 14601 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 045 Passed codes NEXT STEPS 19 Failed codes CD 20 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07/08/2025 @ 14:55 $80 annual inspection fee BRAD BALDWIN - 07/10/2025 @ 07:18 Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 07/10/2025 @ 07:18 Reinspection Date 07/3112025 Provide corrections to avoid progressive re -inspection fees beginning at $100. BeerlLiquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07/10/2025 @ 07:18 If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection RQ Aurora Torres Date: BRAD BALDWIN 07/10/2025 CHECKLISTS GENERATED ON 7/10/25, 7:30 AM 1 OF 11 Emergency Equipment Status code Fait Fail 0 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Description Location: Dining area Comments: Repair or replace west emergency lighting that failed to illuminate during testing, Location: Dining area Comments: Repair or replace east emergency lighting fixture GENERATED ON 7/10/25, 7:30 AM 2 OF 11 Additional Codes status Code Fail Fail Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 606.1 - General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code . Description Location: Food prep area Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: Saladlvegetable cooler Comments: Remove plug from power strip. Cooler shall be plugged directly to wall outlet. Location: Near small (west) door in kitchen Comments: Remove crock pot from power strip. Crock pot shall be plugged directly to wall outlet. Location: Kitchen hood GENERATED ON 7/10/25, 7:30 AM 3 OF 11 Fail Fail 606.1 - General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code . 904.13.5.2 - Extinguishing system service. Automatic fire -extinguishing systems shall be serviced not less frequently than every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Location: Kitchen hood Comments: Repair or replace oven vent to comply with Mechanical Code. Code questions shall be directed to Chief Mechanical Inspector, Brian Baker. GENERATED ON 7/10/25, 7:30 AM 4 OF 11 Electrical Safety Status Code Fail Fail 0 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Walk-in fridge Comments: Provide moisture proof covers for light fixtures. Location: Electric panel in kitchen Comments: Remove obstructions within 36" clearance required in front of electric panel. GENERATED ON 7/10/25, 7:30 AM 5 OF 11 Fail Fail Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Kitchen near cooktop & microwave Comments: Remove multi -plug cord above cooktop. Location: Behind hostess stand Comments: Remove multi -plug extension cord to table pager devices. Devices shall be plugged to wall outlet or power strip with manual reset plugged to wall outlet. Location: Kitchen above beer fridge & chips station Comments: Properly mount power strip to wall or solid surface or support on shelf. GENERATED ON 7/10/25, 7:30 AM 6 OF 11 Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Near dishwashing area Comments: Properly mount power strip to wall or solid surface or support on shelf. GENERATED ON 7/10/25, 7:30 AM 7 OF 11 Commercial Cooking Hood Suppression System Status Code Fail Fail Fail 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSIIIKECA C10. 904.13.5.2 - Extinguishing system service. Automatic fire -extinguishing systems shall be serviced not less frequently than every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Descr p on Location: Kitchen hood suppression system Comments: Provide service to suppression system, currently 171 dasy past due as of 7/8I25. Contractor shall upload report of service to Compliance Engine. Location: Near 6 burner range Comments: Grease accumulation shall be cleaned. Location: Six burner range Comments: Move range to be 6 inches inside of outer edge of hood exhaust system. GENERATED ON 7/10/25, 7:30 AM 8 OF 11 Fire Resistant Construction Maintenance Status. Code Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Outside men's bathroom Comments: Replace missing ceiling tile. GENERATED ON 7/10/25, 7:30 AM 9 OF 11 Portable Fire Extingusihers Status rode. Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Near main entrance Comments: Install properly serviced fire extinguisher on wall bracket no less than 4" from floor and no more than 5 ft from floor in height near front entry. GENERATED ON 7/10/25, 7:30 AM 10 OF 11 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Date Paid Amount Paid invoice Number N/A Check Number N/A Transaction Number NIA GENERATED ON 7/10/25, 7:30 AM 11 OF 11