COMMERCIAL INSPECTION - 441 E TOWER PARK DR - 7-8-25
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
21369
07/11/2025
08/15/2025
2026-00000030
$80.00
Less Prepayment
Total Due -*
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
a) 69
Waterloo Fire Rescue
Inspection Report
Chilitos Mexican Bar - 441 E Tower Park DR, BLDG 441 E Tower Park Dr, Waterloo IA
50702
INSPECTION DETAILS
Inspection Date
07/08/2025
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
NIA
425 E. 3rd Street
Inspection Number
14601
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
045
Passed codes
NEXT STEPS
19
Failed codes
CD 20
NIA codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 07/08/2025 @ 14:55
$80 annual inspection fee
BRAD BALDWIN - 07/10/2025 @ 07:18
Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 07/10/2025 @ 07:18
Reinspection Date
07/3112025
Provide corrections to avoid progressive re -inspection fees beginning at $100. BeerlLiquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 07/10/2025 @ 07:18
If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections
& re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees
start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
RQ
Aurora Torres Date: BRAD BALDWIN 07/10/2025
CHECKLISTS
GENERATED ON 7/10/25, 7:30 AM 1 OF 11
Emergency Equipment
Status code
Fait
Fail
0
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
Description
Location: Dining area
Comments: Repair or replace west emergency lighting that failed to
illuminate during testing,
Location: Dining area
Comments: Repair or replace east emergency lighting fixture
GENERATED ON 7/10/25, 7:30 AM 2 OF 11
Additional Codes
status Code
Fail
Fail
Fail
Fail
5303.5.3 - Securing compressed gas containers, cylinders
and tanks.
Compressed gas containers, cylinders and tanks shall be
secured to prevent falling caused by contact, vibration or
seismic activity. Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object
with one or more restraints. 2.Securing containers, cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers, cylinders or tanks.
3. Nesting of compressed gas containers, cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public. Nesting shall be allowed
provided that the nested containers, cylinders or tanks, if
dislodged, do not obstruct the required means of egress.
4.Securing of compressed gas containers, cylinders and
tanks to or within a rack, framework, cabinet or similar
assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of
examination, filling, transport or servicing.
603.1.1 - Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
606.1 - General.
Commercial kitchen exhaust hoods shall comply with the
requirements of the International Mechanical Code .
Description
Location: Food prep area
Comments: Secure compressed gas cylinders with chain to avoid tip
over.
Location: Saladlvegetable cooler
Comments: Remove plug from power strip. Cooler shall be plugged
directly to wall outlet.
Location: Near small (west) door in kitchen
Comments: Remove crock pot from power strip. Crock pot shall be
plugged directly to wall outlet.
Location: Kitchen hood
GENERATED ON 7/10/25, 7:30 AM
3 OF 11
Fail
Fail
606.1 - General.
Commercial kitchen exhaust hoods shall comply with the
requirements of the International Mechanical Code .
904.13.5.2 - Extinguishing system service.
Automatic fire -extinguishing systems shall be serviced not
less frequently than every six months and after activation of
the system. Inspection shall be by qualified individuals, and a
certificate of inspection shall be forwarded to the fire code
official upon completion.
Location: Kitchen hood
Comments: Repair or replace oven vent to comply with Mechanical
Code. Code questions shall be directed to Chief Mechanical
Inspector, Brian Baker.
GENERATED ON 7/10/25, 7:30 AM 4 OF 11
Electrical Safety
Status Code
Fail
Fail
0
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
603.4 - Working space and clearancesclearance.
A working space of not Working space around electrical
equipment shall be provided in accordance with Section
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space
shall be not less than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under -floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 mm).
Description
Location: Walk-in fridge
Comments: Provide moisture proof covers for light fixtures.
Location: Electric panel in kitchen
Comments: Remove obstructions within 36" clearance required in
front of electric panel.
GENERATED ON 7/10/25, 7:30 AM
5 OF 11
Fail
Fail
Fail
603.5 - Relocatable power taps and current taps.Multiplug
adapters.
Multiplug adapters, such as cube adapters, unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
603.5 - Relocatable power taps and current taps.Multiplug
adapters.
Multiplug adapters, such as cube adapters, unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
603.5.3 - Installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
Location: Kitchen near cooktop & microwave
Comments: Remove multi -plug cord above cooktop.
Location: Behind hostess stand
Comments: Remove multi -plug extension cord to table pager
devices. Devices shall be plugged to wall outlet or power strip with
manual reset plugged to wall outlet.
Location: Kitchen above beer fridge & chips station
Comments: Properly mount power strip to wall or solid surface or
support on shelf.
GENERATED ON 7/10/25, 7:30 AM 6 OF 11
Fail
603.5.3 - Installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
Location: Near dishwashing area
Comments: Properly mount power strip to wall or solid surface or
support on shelf.
GENERATED ON 7/10/25, 7:30 AM 7 OF 11
Commercial Cooking Hood Suppression System
Status Code
Fail
Fail
Fail
606.3.3.1 - Inspection.
Hoods, grease -removal devices, fans, ducts and other
appurtenances shall be inspected at intervals specified in
Table 606.3.3.1 or as approved by the fire code official.
Inspections shall be completed by qualified individuals.
606.3.3.2 - Grease accumulation.
If during the inspection it is found that hoods, grease -removal
devices, fans, ducts or other appurtenances have an
accumulation of grease, such components shall be cleaned in
accordance with ANSIIIKECA C10.
904.13.5.2 - Extinguishing system service.
Automatic fire -extinguishing systems shall be serviced not
less frequently than every six months and after activation of
the system. Inspection shall be by qualified individuals, and a
certificate of inspection shall be forwarded to the fire code
official upon completion.
Descr
p
on
Location: Kitchen hood suppression system
Comments: Provide service to suppression system, currently 171
dasy past due as of 7/8I25. Contractor shall upload report of service
to Compliance Engine.
Location: Near 6 burner range
Comments: Grease accumulation shall be cleaned.
Location: Six burner range
Comments: Move range to be 6 inches inside of outer edge of hood
exhaust system.
GENERATED ON 7/10/25, 7:30 AM
8 OF 11
Fire Resistant Construction Maintenance
Status. Code
Fail
704.1 - Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Description
Location: Outside men's bathroom
Comments: Replace missing ceiling tile.
GENERATED ON 7/10/25, 7:30 AM
9 OF 11
Portable Fire Extingusihers
Status rode.
Fail
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Description
Location: Near main entrance
Comments: Install properly serviced fire extinguisher on wall bracket
no less than 4" from floor and no more than 5 ft from floor in height
near front entry.