Loading...
HomeMy WebLinkAbout117 E SAN MARNAN DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/08/2025 09/15/2025 2026-00000063 $200.00 Customer #: 24676 THE SPOT #3 117 E SAN MARNAN DR WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 117 E SAN MARNAN DR - 8-8-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION 3 Total Price $200.00 CUSTOMER # BILLINGDATE DUE DATE INVOICE # CHARGES 24676 08/08/2025 09/15/2025 2026-00000063 $200.00 Less Prepayment Total Due —> City of Waterloo $0.00 $200.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report The Spot#3 117 E.San Marnan DR, BLDG 117 E San Marnan Dr, Waterloo IA 50702 INSPECTION DETAILS inspection Date 0810812025 Lead Inspector BRAD BALDWIN a(4 (p 425 E. 3rd Street Inspection Type Inspection Number Annual Inspection (1Yr) *BMW EGTIt)N 16174-R7 Other Inspectors N/A Shitt NIA Station Unit N/A NIA SUMMARY OF INSPECTION O 0 Passed codes NEXT STEPS 0 Resolved violations 0 5 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/08/2025 @ 08:09 $200 re -inspection fee for failure to correct violations as of 6111/25 BRAD BALDWIN - 07/1112025 @ 06:58 -Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 08/29/2025 BRAD BALDWIN - 07/1112025 @ 06:58 If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. ****"Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 07/1112025 @ 06:58 annual inspection $80 BRAD BALDWIN - 07/11/2025 @ 06:58 Re -inspection fee $100 BRAD BALDWIN - 07/1112025 @ 06:58 fees increase each re -inspection incremently to $200 BRAD BALDWIN - 07/11/2025 @ 06:58 Re -inspection fee $150 BRAD BALDWIN - 07/11/2025 @ 06:58 provide all corrections to avoid further re -inspection fees. BRAD BALDWIN - 07111/2025 @ 06:58 No re -inspection fee today because some progress made. Provide ALL corrections to avoid re -inspection fees at next inspection. BRAD BALDWIN - 07111/2025 @ 06:58 GENERATED ON 8/825, 8:19 AM 1 OF 5 $200 re -inspection fee on 7/10125 BRAD BALDWIN - 08/08/2025 @ 08:10 $200 re -inspection fee for failure to correct violations as of 8/7/25 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Malik (2025) CHECKLISTS -ER Date: BRAD BALDWIN 08/0812025 GENERATED ON 8/8/25, 8:19 AM 2 OF 5 Additional Codes Status Code Fail Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 5304.1 - Upright storage. Compressed gas containers, cylinders and tanks, except those designed for use in a horizontal position, and all compressed gas containers, cylinders and tanks containing nonliquefied gases, shall be stored in an upright position with the valve end up. An upright position shall include conditions where the container, cylinder or tank axis is inclined as much as 45 degrees (0.80 rad) from the vertical. Exceptions: 1. Compressed gas containers with a water volume less than 1.3 gallons (5 L) are allowed to be stored in a horizontal position. 2.Cylinders, containers and tanks containing nonflammable gases, or cylinders, containers and tanks containing nonliquefied flammable gases that have been secured to a pallet for transportation purposes. 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Back storage shelf near electrical panel Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: CO2 tank back storage Comments: Tank laying horizontal on shelf shall be upright and chained to prevent tip over Location: Back storage near electrical panel Comments: Replace all missing ceiling tiles. GENERATED ON 8/8/25, 8:19 AM 3 OF 5 Reinspection status code. Fail Fail 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: Beverage fridge at end of cashier counter Comments: Appliance cord has been altered, obtain licensed electrician to repair cord, email copy of receipt of repair from contractor to inspector. Additional comments: No documentation of electrical contractor repairs. Electrical inspector has not been contacted as of 8/8/25. Location: Near fountain soda machines Comments: Remove freezer cord from aisle walkway area to avoid trip and shock hazard. Additional comments: No documentation of electrical contractor repairs. Electrical inspector has not been contacted as of 8/8/25. GENERATED ON 8/8/25, 8:19 AM 4 OF 5 Statement of Fees FEE Invoice Date NIA Inspection Fee $200.00 Date Paid Amount Paid Invoice Number Check Number Transaction Number NIA NIA N/A GENERATED ON 8/8/25, 8:19 AM 5 OF 5