Loading...
HomeMy WebLinkAbout1104 WASHINGTON STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/08/2025 09/15/2025 2026-00000057 $100.00 Customer #: 22022 GYRO HUT 1104 WASHINGTON ST WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1104 WASHINGTON ST - 8-7-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION 1 Total Price $100.00 CUSTOMER # 22022 BILLING DATE 08/08/2025 DUE DATE 09/15/2025 INVOICE # 2026-00000057 CHARGES $100.00 Less Prepayment Total Due —� City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Gyro Hut - 1104 Washington ST, BLDG 1104 Washington St - STE B, Waterloo IA 50702 INSPECTION DETAILS Inspection Date %, 08I0712025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) REINSPECTION Other Inspectors NIA 425 E. 3rd Street Inspection Number 15438-R1 Shin Station Unit NIA N/A NIA SUMMARY OF INSPECTION O 0 Passed codes NEXT STEPS 3 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07/17/2025 @ 15:40 $80 annual inspection fee BRAD BALDWIN - 07/17/2025 @ 15:40 Fire extinguishers due serviced by September 2025 BRAD BALDWIN - 07/17/2025 @ 15:40 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 07/17/2025 @ 15:40 Reinspection Date 08/28/2025 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07/1712025 @ 15:40 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 08/07/2025 @ 13:02 s- 7.00 re -inspection fee (817/25) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection aR Mohammad ILYAS-owner Date: BRAD BALDWIN 0810712025 GENERATED ON 8/7/25, 1:03 PM 1 OF 3 CHECKLISTS Reinspection Status Code Fail Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Desc P on Location: Tanks near front entrance Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: Kitchen storage area near electric panel Comments: Pressure cooker and crock pot shall be plugged directly to wall outlet, remove from power strip. Adding an additional outlet requires licensed electrical contractor to obtain permit and inspection. Location: Kitchen hood suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 126 days past due as of 7117/25. Additional comments: Currently 147 days past due as of 817125 GENERATED ON 8/7/25, 1:03 PM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA 5100.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 8/7/25, 1:03 PM 3 OF 3