Loading...
HomeMy WebLinkAbout4018 UNIVERSITY AVECustomer #: 3448 CASEY'S 218 4014 UNIVERSITY AV WATERLOO, IA 50701 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/08/2025 09/15/2025 2026-00000054 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 4018 UNIVERSITY AVE - 8-5-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 3448 BILLING DATE 08/08/2025 DUE DATE 09/15/2025 INVOICE # 2026-00000054 CHARGES $80.00 Less Prepayment Total Due City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 3 u� Waterloo Fire Rescue Inspection Report Casey's 218 Pub - 4010 - 4018 University AVE, BLDG 4010 - 4018 University Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Dam 08/05/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 14747 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 42 0 12 Q 22 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/05/2025 @ 13:44 $80 annual inspection fee BRAD BALDWIN - 08106/2025 @ 07:02 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 08/0612025 @ 07:02 Reinspection Date 08/2712025 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/06/2025 @ 07:02 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Jeremy Ades 2025 Date: CHECKLISTS BRAD BALDWIN 08/0612025 GENERATED ON 8/6/25, 7:06 AM 1 OF 8 Emergency Equipment Cedes Code Fail Fail Fail 0 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Pool hall (west side) near Busch Light neon sign Comments: Repair or replace emergency egress lighting that failed to illuminate during testing. Location: Pool hall (west) Comments: Repair or replace exit sign above SW exterior exit door that failed to illuminate during testing. Location: Exterior beer garden Comments: Repair or replace exit sign that failed to illuminate during testing. GENERATED ON 8/6/25, 7:06 AM 2 OF 8 Electrical Safety Status Code Fail Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. D -scription Location: Arcade area mechanical room Comments: Remove obstructions within 36" of electric panel, maintain clear path. Location: Arcade area checkout stand Comments: Remove power tap from power tap, plug directly to wall outlet. GENERATED ON 8/6/25, 7:06 AM 3 OF 8 ((Fail 0 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Pool hall (west) Comments: Remove power strip from power strip, plug directly to wall outlet. Location: Arcade area mechanical room Comments: Properly mount power strip on wall or support on shelf to avoid hanging by wires. GENERATED ON 8/6/25, 7:06 AM 4 OF 8 Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Location: Pool hall (west) Comments: Properly hang power strip on ceiling to avoid hanging by wires. Location: Pool hall (west) Comments: Christmas lights allowed temporarily for 90 days, must be taken down by 914/25. GENERATED ON 8/6/25, 7:06 AM 5 OF 8 Commercial Cooking Hood Suppression System Status Code Fail 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSIIIKECA C1O. Fire Resistant Construction Maintenance Status Code Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer&#O39;s installation instructions. Location: Kitchen hood exhaust system Comments: Clean grease filters oe,cription Location: Front vestibule Comments: Replace missing ceiling tiles. GENERATED ON 8/6/25, 7:06 AM 6 OF 8 Portable Fire Extingusihers Status Cede Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Comments: Provide annual service to all fire extinguishers, last serviced February 2024. GENERATED ON 8/6/25, 7:06 AM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number N/A NIA GENERATED ON 8/6/25, 7:06 AM 8 OF 8