Loading...
HomeMy WebLinkAbout4550 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/08/2025 09/15/2025 2026-00000053 $100.00 Customer #: 15249 BAMBOO RIDGE CAMPGROUND 4550 HESS RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 4550 LA PORTE RD - 7-29-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 15249 08/08/2025 09/15/2025 2026-00000053 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Bamboo Ridge - 4550 La Porte RD, BLDG 4550 La Porte Road, Waterloo IA 50702 INSPECTION DETAILS n Date 07/29/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 15408 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 44 Passed codes NEXT STEPS 0 12 Failed codes 0 23 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07/29/2025 @ 11:12 Fire extinguishers due annually serviced September 2025. BRAD BALDWIN - 07/29/2025 @ 15:29 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224 BRAD BALDWIN - 07129/2025 @ 15:29 Reinspection Date 08/21/2025 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07129/2025 @ 15:29 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 07/29/2025 @ 15:32 S100..atinuaioinstietthtinItee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Matt Abben (2025) Date: BRAD BALDWIN 07/29/2025 CHECKLISTS GENERATED ON 7/29/25, 3'32 PM 1 OF 4 Additional Codes Status Fail l:d Fail Fail 102.4 - Application of budding code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Emergency Equipment Status Gode Fail Fail Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Location: 2 park model homes by bath house Comments: Obtain building and electrical permits and inspections for installation of park models, decks, and electrical Location: Gas station electrical room Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: Commercial and guest clothes dryers Comments: Provide documentation of cleaning of dryer vent from appliance to the outside of the building with signature and date. Email documentation to fire inspector. Description Location: Gas station electric room Comments: Repair or replace egress lighting that failed to illuminate during testing. Location: Wai women's shower room Comments: Repair or replace egress lighting closest to shower that failed to illuminate during testing. Location: Wai men's shower room Comments: Repair or replace both egress lights that failed to illuminate during testing. Location: Lua men's shower room Comments: Repair or replace egress lighting closest to showers that failed to illuminate during testing. GENERATED ON 7/29/25, 3:32 PM 2 OF 4 Electrical Safety Status Code Fail Fail 0 Fail Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Description Location: Wai shower house Comments: Install appropriate cover to east exterior outlet. Location: Maintenance garage Comments: Remove obstructions within 36" of electric panel, maintain clear path. Location: Gas station near ATM Comments: Remove multi -plug adapter, may replace with power strip with manual reset. Location: Gas station ITlsump pump room Comments: Remove power strip plugged to other power strip near sump pump. Location: Maintenance garage mechanical room Comments: Remove extension cord to deep freezer. Relocate freezer to plug directly to wall outlet or provide new outlet by licensed contractor with permits and inspections obtained. GENERATED ON 7/29/25, 3:32 PM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee N/A $100.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 7/29/25, 3:32 PM 4 OF 4 a