Loading...
HomeMy WebLinkAbout3551 UNIVERSITY AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/08/2025 09/15/2025 2026-00000052 $80.00 Customer #: 24760 ASPIRE DANCE STUDIO 3551 UNIVERSITY AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3551 UNIVERSITY AVE - 7-31-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24760 08/08/2025 09/15/2025 2026-00000052 $80.00 Less Prepayment Total Due — City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Aspire Dance Studio - 3551 University 50701 INSPECTION DETAILS E, BLDG 3551 University Ave, Waterloo IA g(tibi/e) 425 E. 3rd Street Inspection Date Inspection Type Inspection Number 07/31/2025 Annual Inspection (1Yr) 17368 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other inspectors NIA SUMMARY OF INSPECTION 045 Passed codes NEXT STEPS U 18 ® 20 Fallen codes N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07/3112025 @ 15:27 $80 annual inspection tee BRAD BALDWIN - 07/31/2025 @ 15:27 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 07/31/2025 @ 15:27 Reinspection Date 08/27/2025 It all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 07/31/2025 @ 15:28 • -Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone # 319-291- 2515. BRAD BALDWIN - 08104/2025 @ 08:22 Fire extinguishers due annually serviced by Sept 2025 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Alexis Roling Date: CHECKLISTS BRAD BALDWIN 08/04/2025 GENERATED ON 8/4/25. 8:30 AM 1 OF 8 Means of Egress Status Code Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Description Location: Rear exit door Comments: Repair or replace door to allow door to open with less than 15lbs of force. If replacement of door is necessary, permit and inspections shall be obtained. GENERATED ON 8/4/25, 9:30 AM 2 OF 8 Emergency Equipment >taius Code Fail Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Location: Outside Dance Shop Comments: Repair or replace lights that failed to illuminate during testing. Location: Outside Studio 2 Comments: Repair or replace lights to operate as manufactured. Location: Studio 2 bathroom Comments: Repair or replace lighting to operate as manufactured. Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress Location: Above receptionist desk illumination in accordance with Sections 1008.3 and 1104.5.1. Comments: Repair or replace egress lights that failed to illuminate during testing. Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Location: Dancers lounge Comments: Repair or replace lights that failed to illuminate during testing. Location: Front lobby men's bathroom Comments: Repair or replace lights near mechanical room that failed to illuminate during testing. GENERATED ON 8/4/25, 9:30 AM 3 OF 8 Fail Fail Fail x 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress Location: Dancer's lounge bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments: Repair or replace lights to operate as manufactured. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not Tess than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Fire Sprinkler System status Code Fail 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Fire Service Features Status Code Fail 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. Location: Front lobby women's bathroom Comments: Repair or replace lights near showers that failed to illuminate during testing. Location: Studio 2 exterior exit door Comments: Repair or replace exit sign and egress lights that failed to illuminate during testing. Location: Studio 2 Comments: Repair or replace exit sign and egress lights that failed to illuminate during testing. Description Location: Front vestible Comments: Escutcheon loose to ceiling shall be tight to ceiling. Description Location: Near front entrance Comments: Contact Fire Department to update Knox Box with current keys to access building in emergency. GENERATED ON 8/4/25, 9:30 AM 4 OF 8 Electrical Safety Status Code Fail 603.4 - Working space and clearancesciearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Near rear exit Comments: Maintain clear path and 36" clearance around electric panel. GENERATED ON 8/4/25, 9:30 AM 5 OF 8 Fire Resistant Construction Maintenance Status Code Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Portable Fire Extingusihers Status FailF(/ Fail Code 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Description Location: Several fire rated doors within space. Comments: Remove all paint or any obstruction to fire door tags. Tags must not be altered and shall maintain legible. Description Location: Parent viewing room Comments: Fire extinguisher shall be properly mounted on wall bracket within 4" to 5' from floor. Location: Dance shop Comments: Fire extinguisher shall be properly mounted on wall bracket within 4" to 5' from floor. GENERATED ON 8/4/25, 9:30 AM 6 OF 8 Additional Codes Status Code Fail 0 907.4.2.6 - Unobstructed and unobscured. Manual fire alarm boxes shall be provided with ready access, unobstructed, unobscured and visible at all times. Description Location: Near rear exit Comments: Remove obstructions to clear path of fire alarm pull station. GENERATED ON 8/4/25, 9:30 AM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 8/4/25, 9:30 AM 8 OF 8