COMMERCIAL INSPECTION - 32 LAFAYETTE - 8-15-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24761
08/18/2025
09/20/2025
2026-00000088
$80.00
Less Prepayment
Total Due -->
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
ffi Inspection Report
Lounge Bar - 32 Lafayette ST, BLDG 32 Lafayette St, Waterloo IA 50703
INSPECTION DETAILS
Inspection Date
08/15/2025
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
other Inspectors
N/A
425 E. 3rd Street
Inspection Number
17476
Shift Station Unit
NIA NIA N/A
SUMMARY OF INSPECTION
0 31
Passed codes
NEXT STEPS
0 9
Failed codes
34
NIA codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 08/15/2025 @ 12:44
$80 annual inspection fee
BRAD BALDWIN - 08/15/2025 @ 13:42
Reinspection Date
09/05/2025
8114/25- Kitchen appliances currently disconnected from service, not in use. All fire protection services in kitchen must be updated and serviced before
use of kitchen.
BRAD BALDWIN - 08/1512025 @ 13:42
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 08/1512025 @ 13:42
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 08/15/2025 @ 13:43
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Launy Souverance (2025) Owners Son
CHECKLISTS
GENERATED ON 8/15/25, 1:44 PM
Date:
leg
BRAD BALDWIN 08/15/2025
1 OF 5
Means of Egress
>tatus, c.
Fail
1010.2.5 - Bolt locks.
Manually operated flush bolts or surface bolts are not
permitted. Exceptions: 1.On doors not required for egress in
individual dwelling units or sleeping units. 2.Where a pair of
doors serves a storage or equipment room, manually
operated edge- or surface -mounted bolts are permitted on the
inactive leaf. 3.Where a pair of doors serves an occupant load
of less than 50 persons in a Group B, F or S occupancy,
manually operated edge- or surface -mounted bolts are
permitted on the inactive leaf. The inactive leaf shall not
contain doorknobs, panic bars or similar operating hardware.
4.Where a pair of doors serves a Group B, F or S occupancy,
manually operated edge- or surface -mounted bolts are
permitted on the inactive leaf provided that such inactive leaf
is not needed to meet egress capacity requirements and the
building is equipped throughout with an automatic sprinkler
system in accordance with Section 903.3.1.1. The inactive leaf
shall not contain doorknobs, panic bars or similar operating
hardware. 5.Where a pair of doors serves patient care rooms
in Group 1-2 occupancies, self -latching edge- or surface -
mounted bolts are permitted on the inactive leaf provided that
the inactive leaf is not needed to meet egress capacity
requirements and the inactive leaf shall not contain
doorknobs, panic bars or similar operating hardware.
Fire Service Features
Staius Code
Fail
505.1 - Address identification.
New and existing buildings shall be provided with approved
address identification. The address identification shall be
legible and placed in a position that is visible from the street
or road fronting the property. Address identification
characters shall contrast with their background. Address
numbers shall be Arabic numbers or alphabetical letters.
Numbers shall not be spelled out. Each character shall be not
less than 4 inches (102 mm) high with a minimum stroke
width of 112 inch (12.7 mm). Where required by the fire code
official, address identification shall be provided in additional
approved locations to facilitate emergency response. Where
access is by means of a private road and the building cannot
be viewed from the public way, a monument, pole or other
sign or means shall be used to identify the structure. Address
identification shall be maintained.
Description
Location: Front entrance double doors
Comments: Slide bolt lock shall be removed from doors.
Description
Comments: Install address numbers contrasting with the exterior of
building in inconspicuous location.
GENERATED ON 8/15/25, 1'44 PM 2 OF 5
Electrical Safety
Status Code
Fail
Fail
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Fail 603.5 - Relocatable power taps and current taps.Multiplug
adapters.
Multiplug adapters, such as cube adapters, unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
Fail
603.5.3 - installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
Description
Location: Bar beverage cooler
Comments: Remove cooler from power strip, cooler shall be plugged
directly to wall outlet. If adding additional outlet, a licensed electrical
contractor must obtain permit and inspections.
Location: Northeast corner of exterior
Comments: Provide proper cover for exterior outlet.
Location: Upper lounge east wall
Comments: Provide proper cover to outlet
Location: Upper lounge area east wall
Comments: Remove multi -plug adapter, power strip with manual
reset properly mounted would be acceptable.
Location: Bar near projector screen
Comments: Properly mount power strip to wall or support on shelf to
avoid hanging by wires.
GENERATED ON 8/15/25, 1:44 PM
3 OF 5
Portable Fire Extingusihers
gat,,.= Goa
Fail
Fail
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
906.7 - Hangers and brackets.
Hand-held portable fire extinguishers, not housed in cabinets,
shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the
mounting surface in accordance with the manufacturer's
installation instructions.
ion
Comments: Provide annual service to all fire extinguishers in
building. Current extinguishers due August 2025
Location: Rear exit door
Comments: Properly mount serviced fire extinguisher on wall
between 4" and 5' from floor.