Loading...
HomeMy WebLinkAbout32 LAFAYETTEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/18/2025 09/20/2025 2026-00000088 $80.00 Customer #: 24761 LOUNGE BAR 32 LAFAYETTE ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 32 LAFAYETTE - 8-15-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24761 08/18/2025 09/20/2025 2026-00000088 $80.00 Less Prepayment Total Due --> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue ffi Inspection Report Lounge Bar - 32 Lafayette ST, BLDG 32 Lafayette St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 08/15/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) other Inspectors N/A 425 E. 3rd Street Inspection Number 17476 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 31 Passed codes NEXT STEPS 0 9 Failed codes 34 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/15/2025 @ 12:44 $80 annual inspection fee BRAD BALDWIN - 08/15/2025 @ 13:42 Reinspection Date 09/05/2025 8114/25- Kitchen appliances currently disconnected from service, not in use. All fire protection services in kitchen must be updated and serviced before use of kitchen. BRAD BALDWIN - 08/1512025 @ 13:42 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 08/1512025 @ 13:42 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/15/2025 @ 13:43 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Launy Souverance (2025) Owners Son CHECKLISTS GENERATED ON 8/15/25, 1:44 PM Date: leg BRAD BALDWIN 08/15/2025 1 OF 5 Means of Egress >tatus, c. Fail 1010.2.5 - Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1.On doors not required for egress in individual dwelling units or sleeping units. 2.Where a pair of doors serves a storage or equipment room, manually operated edge- or surface -mounted bolts are permitted on the inactive leaf. 3.Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge- or surface -mounted bolts are permitted on the inactive leaf. The inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. 4.Where a pair of doors serves a Group B, F or S occupancy, manually operated edge- or surface -mounted bolts are permitted on the inactive leaf provided that such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. 5.Where a pair of doors serves patient care rooms in Group 1-2 occupancies, self -latching edge- or surface - mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. Fire Service Features Staius Code Fail 505.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 112 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Description Location: Front entrance double doors Comments: Slide bolt lock shall be removed from doors. Description Comments: Install address numbers contrasting with the exterior of building in inconspicuous location. GENERATED ON 8/15/25, 1'44 PM 2 OF 5 Electrical Safety Status Code Fail Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Fail 603.5.3 - installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Description Location: Bar beverage cooler Comments: Remove cooler from power strip, cooler shall be plugged directly to wall outlet. If adding additional outlet, a licensed electrical contractor must obtain permit and inspections. Location: Northeast corner of exterior Comments: Provide proper cover for exterior outlet. Location: Upper lounge east wall Comments: Provide proper cover to outlet Location: Upper lounge area east wall Comments: Remove multi -plug adapter, power strip with manual reset properly mounted would be acceptable. Location: Bar near projector screen Comments: Properly mount power strip to wall or support on shelf to avoid hanging by wires. GENERATED ON 8/15/25, 1:44 PM 3 OF 5 Portable Fire Extingusihers gat,,.= Goa Fail Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. ion Comments: Provide annual service to all fire extinguishers in building. Current extinguishers due August 2025 Location: Rear exit door Comments: Properly mount serviced fire extinguisher on wall between 4" and 5' from floor. GENERATED ON 8/15/25, 1:44 PM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A NIA GENERATED ON 8/15/25, 1:44 PM 5 OF 5