Loading...
HomeMy WebLinkAbout111 E DONALD,ifrrat'. INVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/18/2025 09/20/2025 2026-00000087 $80.00 Customer #: 23301 KWIK STAR 111 E DONALD ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 111 E DONALD - 8-18-25 FOR BILLING INQUIRY: (319)291-4323 Description, Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23301 08/18/2025 09/20/2025 2026-00000087 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Kwik Star - 111 E Donald ST, BLDG 111 E Donald St, Waterloo IA 50703 INSPECTION DETAILS inspection Gate 08118/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 14816 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 49 Passed codes NEXT STEPS (J 6 soled codes 19 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/18/2025 @ 14:51 $80 annual inspection fee BRAD BALDWIN - 08/18/2025 @ 14:51 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 09/10I2025 BRAD BALDWIN - 08118/2025 @ 14:51 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/18/2025 @ 14:51 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Alicia 2025-store leader Date: CHECKLISTS BRAD BALDWIN 08/1812025 GENERATED ON 8/18/25, 2:53 PM 1 OF 4 Means of Egress Stat€,ts Code Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Emergency Equipment Status Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. t>C5cripiion Location: Exit door near fountain drinks Comments: Repair or replace exit door to allow to open with less than 15lbs of force. Description Location: Near milk cooler and kitchen entrance Comments: Repair or replace egress lighting that failed to illuminate during testing Location: Front entry vestibule Comments: Repair or replace egress lighting that failed to illuminate during testing Location: Exit door near beer cave Comments: Repair or replace exit sign and emergency egress lighting that failed to illuminate during testing GENERATED ON 8/18/25, 2:53 PM 2 OF 4 Fire Service Features Status Code Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Electrical Safety Status Lode Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Description Location: Kitchen electric panels Comments: Remove paperwork to avoid disguising panels for quick access to firefighters. Description Location: Behind food warming station Comments: Remove orange extension cord. GENERATED ON 8/18/25, 2:53 PM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA N/A GENERATED ON 8/18/25, 2:53 PM 4 OF 4