COMMERCIAL INSPECTION - 3631 W 9TH ST - 8-14-25
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
24164
BILLING DATE
08/18/2025
DUE DATE
09/20/2025
INVOICE #
2026-00000084
CHARGES
$80.00
Less Prepayment
TotalDue —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
It Takes A Village Childcare - 3631 W 9th ST, BLDG 3631 W. 9th St., Waterloo IA
50702
INSPECTION DETAILS
Inspection Date
08/14/2025
Lead Inspector
JEREMIAH VANDYKE
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
N/A
425 E. 3rd Street
Inspection Number
15471
Shift Station Unit
N/A N/A N/A
SUMMARY OF INSPECTION
0 45
Passed codes
NEXT STEPS
03 026
Failed codes NIA codes
Please direct questions about your Inspection to:
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE - 08/14/2025 @ 14:16
4118/2025 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Compliant Compliant
JEREMIAH VANDYKE - 08/14/2025 @ 14:16
Fire extinguishers serviced by Superior Fire October 2024.
JEREMIAH VANDYKE - 08/14/2025 @ 14:17
Last recorded fire drill completed July l6th 2025.
Reinspection Date
09/13/2025
JEREMIAH VANDYKE - 08/14/2025 @ 14:33
Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are
Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed
the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees
may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.-
JEREMIAH VANDYKE - 08/14/2025 @ 14:33
Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615
JEREMIAH VANDYKE - 08/14/2025 @ 14:33
Inspection Fee = $80.00 (To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 8/14/25, 2:34 PM 1 OF 3
Florence Miller Date:
CHECKLISTS
Means of Egress
State; Code
Fail
1010.1.3 - Door opening force Forces to unlatch and open
doors.
The force for pushing or pulling open interior swinging
egress doors, other than fire doors, shall not exceed 5
pounds (22 N). These forces do not apply to the force
required to retract latch bolts or disengage other devices that
hold the door in a closed position. For other swinging doors,
as well as sliding and folding doors, the door latch shall
release when subjected to a 15-pound (67 N) force. The door
shall be set in motion when subjected to a 30-pound (133 N)
force. The door shall swing to a full -open position when
subjected to a 15-pound (67 N) force. The forces to unlatch
doors shall comply with the following: 1.Where door
hardware operates by push or pull, the operational force to
unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where
door hardware operates by rotation, the operational force to
unlatch the door shall not exceed 28 inch -pounds (315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated, other than doors required to be fire rated, the force
for pushing or pulling open the door shall not exceed 5
pounds (22 N). 2.For other swinging doors, sliding doors or
folding doors, and doors required to be fire rated, the door
shall require not more than a 30-pound (133 N) force to be set
in motion and shall move to a full -open position when
subjected to not more than a 15-pound (67 N) force.
Emergency Equipment
61atus Code
Fail
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
[7escripUo/
Location: Green room and Red room marked exit doors leading to
outside.
Comments: Doors are hard to open and need adjustment.
Location: West entrance 9th street side
Comments: Exit/Egress light tested and failed.
Additional Codes
Status Coda Description
Fail 610.1.2 - Maintenance.
0 The lint trap, mechanical and heating components, and the Location: Dryer cleaning log last recorded April 2024 done by Harris.
exhaust duct system of a clothes dryer shall be maintained in Comments: Dryer cleaning log last recorded April 2024 done by
accordance with the manufacturer's operating Harris.
instructions to prevent the accumulation of lint or debris that
prevents the exhaust of air and products of combustion.
GENERATED ON 8/14/25, 2.34 PM 2 OF 3
Statement of Fees
FEE
Invoice Date Inspection Fee
NIA $80.00
Invoice Number
NIA
Date Paid Amount Paid
Check Number Transaction Number
NIA NIA
GENERATED ON 8/14/25, 234 PM