Loading...
HomeMy WebLinkAbout618 SYCAMORE STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/18/2025 09/20/2025 2026-00000066 $80.00 Customer #: 21840 BROWN DERBY BALLROOM 215 E 4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 618 SYCAMORE ST - 8-13-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 21840 08/18/2025 09/20/2025 2026-00000066 $80.00 Less Prepayment Total Due -� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Brown Derby - 618 SycamoreST, BLDG 618 Sycamore St, Waterloo IA 50703 INSPECTION DETAILS inspection Date 08/13/2025 Lead Inspector BRAD BALDWIN (MIN Inspectors N/A Inspection Type Annual Inspection (1Yr) Shift NIA [,)U 425 E. 3rd Street Inspection Number 14786 Station Unit N/A NIA SUMMARY OF INSPECTION Failed codes NEXT STEPS 0 9` NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/1312025 @ 07:33 $80 annual inspection fee BRAD BALDWIN - 08/13/2025 @ 07:36 Corrected during 8/12/25 Inspection: (1) Removed beverage fridge from power strip in ballroom, plugged to wall outlet. BRAD BALDWIN - 08/1312025 @ 07:40 All occupancies in budding- Provide annual service to all fire extinguishers. Ballroom extinguishers due September 2025 BRAD BALDWIN - 08/13/2025 @ 08:22 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (1/5) - Cell: 319-230-1224 BRAD BALDWIN - 08/13/2025 @ 08:25 Reinspection Date 09/03/2025 Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/13/2025 `c@ 08:25 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature inspector signature No signature Report completed post inspection kristie Seda 2025 Date: BRAD BALDWIN 08/1312025 t ENERATED ON 3/13/25, 8:27 AM 1 OF 6 CHECKLISTS Emergency Equipment Status Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fire Service Features Status Code Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Description Location: Front entry Comments: Repair or replace emergency egress lights on exit sign that failed to illuminate during testing. Location: First floor near office and men's bathroom Comments: Repair or replace emergency egress lights that failed to illuminate during testing. Description Location: Basement sprinkler system Comments: Relocate shelf and all obstructions to maintain clear access for firefighters. GENERATED ON 8/13/25, 8:27 AM 2 OF 6 Electrical Safety Status Code Fail Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Tess, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Liquor room closet Comments: Remove table obstructing access to electric panel, maintain 36" clearance in front of panel and clear path to access. Location: Basement electric service Comments: Remove obstructions within 36" in front of electric panel, maintain clear path to access. GENERATED ON 8/13/25, 8:27 AM 3 OF 6 Fail Fail 0 Fail 0 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Fire Resistant Construction Maintenance Status Code Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Fail 0 Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. 705.2.6 - Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Location: Basement dehumidifier Comments: Remove power strip from extension cord. Power strip must be plugged directly to wall outlet. Location: Liquor room closet Comments: Remove multi -plug extension cord hanging over electric panel. Location: Basement fridge Comments: Remove extension cord from permanent usage. Appliance shall be plugged directly to wall outlet. Adding new outlet would require licensed electrical contractor obtaining permit and inspection. Description Location: 2nd floor kitchenette Comments: Fire door must completely self -close and latch Location: 2nd floor women's bathroom Comments: Fire door must completely self -close and latch Location: First floor office by men's bathroom Comments: Remove foot drop down hold open devices from the fire doors. Must self close and latch. Hold open devices connected to the fire alarm system are allowed Location: Elevator fire door Comments: Provide current annual fire door drop test. Report may be emailed to fire inspector GENERATED ON 8/13/25. 8:27 AM 4 OF 6 Portable Fire Extingusihers Status Code Fail Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Description Location: Basement elevator mechanical room Comments: Provide annual service to fire extinguisher, currently no tag of service or receipt of date of purchase. Location: Liquor room closet Comments: Properly hang fire extinguisher on wall bracket between 4" and 5' from floor. GENERATED ON 8/13/25, 8:27 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA WA GENERATED ON 8/13/25, 8:27 AM 6 OF 6