Loading...
HomeMy WebLinkAbout1024 W 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 08/18/2025 09/20/2025 2026-00000065 $100.00 Customer #: 23189 AMANI COMMUNITY SERVICES 2315 FALLS AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1024 W 4TH ST - 8-11-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # 23189 BILLING DATE 08/18/2025 DUE DATE 09/20/2025 INVOICE # 2026-00000065 CHARGES $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Amani Community Deveolpement - 1024 W 4th ST, BLDG 1024 W 4th St, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 42aas Lead Inspector BRAD BALDWIN Inspection "rype 4nnuaf Inspection (1Yr) Other Inspectors N/A Shift N/A Station N/A 425 E. 3rd Street inspection Number 17435 Unit N/A SUMMARY OF INSPECTION C 34 Pa' t cnris S, NEXT STEPS 0 9 Failed c , i 33 NIA c:ocit,s Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/1112025 (ci, 15:13 $100 annual inspection tee Reinspection Date 09/0512025 BRAD BALDWIN - 08/15/2025 @ 13:56 First floor exit signage options: (1) Remove signs and properly cap electrical in box with cover or provide appropriate covers to signs. (2) Repair or replace signs that fail to remain illuminated during testing BRAD BALDWIN - 08/15/2025 @ 14:07 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - COI: 319-230-1224 BRAD BALDWIN - 08/1512025 rt 14:07 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $1.00, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Evelyn Date: BRAD BALDWIN 08/15/2025 CHECKLISTS GENERATED ON 8/15/25, 2:07 PM 1 OF 6 Means of Egress status Code Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Additional Codes Status Code 1010.2.1- Unlatching. The unlatching of any door or leaf for egress shall require not require more than one operation motion in a single linear or rotational direction to release all latching and all locking devices. Exceptions: 1.Places of detention or restraint. 2.Where manually operated bolt locks are permitted by Section 1010.2.5. 3.Doors with automatic flush bolts as permitted by Section 1010.2.4, Item 3 4. 4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4, Item 4 5. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures Alt electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. :}esi:riptlon Location: Front basement stairs Comments: Remove items on stairs and remove obstructions at base of stairs to maintain clear path of travel of egress. tiescriptaati Location: Front entrance doors Comments: Reconfigure locks/latches to door to avoid more than one motion to unlock and unlatch. Currently deadbolt and separate latching handle requires two motions. Location: Southwest corner office Comments: Remove microwave from power strip. Appliance shall be plugged directly to wall outlet. GENERATED ON 8/15/25, 2:07 PM 2 OF 6 Emergency Equipment atus: Code e Fail Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Basement at bottom of carpeted stairs Comments: Repair or replace emergency egress lighting that failed to illuminate during testing. Location: Basement carpeted room Comments: Repair or replace exit sign and emergency egress lighting that failed to illuminate during testing Location: Exit signs Comments: Main floor exit signs not required per occupancy. See notes for further details. GENERATED ON 8/15/25, 2:07 PM 3 OF 6 Electrical Safety Status Code Fail O Fai I 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: North pink carpeted room Comments: Make necessary repairs or replace outlet that shows signs of damage on north wall. Location: Basement bookshelf Comments: Provide cover to light switch box to avoid shock hazard. GENERATED ON 8/15/25, 2:07 PM 4 OF 6 Portable Fire Extingusihers Status Code Fail 0 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Gescdiptio Comments: Provide annual service to or replace all fire extinguishers with new. Purchasing extinguishers personally, not through contractor requires receipt of purchase taped to bottom of extinguisher. Most current service completed in 2013. GENERATED ON 8/15/25, 2:07 PM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee NIA $100.00 Date Paid Amount Paid invoice Number NIA Check Number NIA Transaction Number NIA GENERATED ON 8/15/25, 207 PM 6 OF 6