KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 6217 DONEGAL CIRCLE #2E - 4-1-25
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION FEE 3RD
Total Price
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24446
04/15/2025
05/20/2025
2025-00000126
$250.00
Less Prepayment
Total Due —
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
6217 DONEGAL CIR #2E, 6025 DONEGAL CIR, BLDG 6217 DONEGAL CIR, WATERLOO IA 50701
DETAILS
Inspection Date: 04/01/2025 j Inspection Type: Rental Inspection j Inspection Number: 14080-R7 j Shift: N/A I Station: N/A I
Unit: N/A I Lead Inspector: Brad Baldwin I Other Inspectors: N/A I Fee: $250.00
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 3 j Passed Codes: 0 j Violations: 5 I N/A Codes: 0
STATUS CODE
1-1 Ai L.
FAIL
DESCRIPTION
R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and
sanitary state? (IPMC 304)
Location: Patio
Original Comment: Railing loose. 304.12 Handrails and guards. Every handrail and
guard shall be firmly fastened and capable of supporting normally imposed loads
and shall be maintained in good condition.
R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Location: Kitchen
Original Comment: Microwave door handle missing. 603.1 Mechanical appliances.
Mechanical appliances, fireplaces, solid fuel -burning appliances, cooking
appliances and water heating appliances shall be properly installed and
maintained in a safe working condition, and shall be capable of performing the
intended function.
Printed on 04/09 2025 f 10:36
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
FAIL
GENERAL NOTES
Location: Bathroom #2
Original Comment: Wall and/or ceiling surface shall be corrected. 305.3 Interior
surfaces. Interior surfaces, including windows and doors, shall be maintained in
good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint
shall be repaired, removed or covered. Cracked or loose plaster, decayed wood
and other defective surface conditions shall be corrected.
Additional Comment: Loose/flaking paint
R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Location: Mechanical closet door
Original Comment: Door hinges loose to jamb shall be corrected.
R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition? (IPMC 603.1)
Location: Mechanical Closet
Original Comment: Pan required under water heater
Brad Baldwin - 04/09/2025 @ 08:07 • Re -inspection fee will be accessed on following inspection if life safety issues not
corrected.
Brad Baldwin - 02/25/2025 @ 06:43 Property Safety Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) -
Cell: 319-464-5605
Printed on 34109.2025 1036
Page 2 of 3
GENERAL NOTES
Brad Baldwin - 02/25/2025 @ 06:43
Brad Baldwin - 02/25/2025 @ 06:43
Brad Baldwin - 02/25/2025 @ 06:43
Brad Baldwin - 04/03/2025 @ 09:35
REINSPECTION DATE
05/13/2025
CONTACT SIGNATURE
Betsy Primeaux
INSPECTOR SIGNATURE
Brad Baldwin
Signed on: 04/09/2025 @ 08:07
QUESTIONS ABOUT YOUR INSPECTION?
Brad Baldwin
brad.baldwin@waterloo-ia.org
3192914319
Re -inspection date is as posted on the inspection report given, the rental unit's
responsible person/s shall reach out prior to set time of that re -inspection. If all
corrections are made before the scheduled inspection, you can call to set up an earlier
re -inspection. Please give the appropriate notices to occupants of the unit/s. Owner or
owners agent must be present during inspections. Failure to schedule a time on the
date given or failure to keep the inspection will result in a $100 fee. *****Re inspection
fees may be assessed for re -inspections. Re -inspection fees start at $50, then $150, and
$250 for all subsequent re -inspections. All appropriate keys to gain entry to locked
units shall be readily available during re -inspection.
10/21/24 - $50.00 Re -inspect fee
$150.00 Re -inspection fee for corrections incomplete
$250.00 Re -inspection fee. Life safety corrections incomplete.