Loading...
HomeMy WebLinkAbout2820 FALLS AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/10/2025 10/15/2025 2026-00000135 $80.00 Customer #: 22167 3 AMIGOS 2820 FALLS AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2820 FALLS AVE - 8-21-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22167 09/10/2025 10/15/2025 2026-00000135 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 S80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Three Amigo's - 2820 Falls AVE, BLDG 2820 Falls Ave, Waterloo IA 50701 INSPECTION DETAILS ir,,,01r h n 001, 0812112025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA Shift NIA 425 E. 3rd Sheet Inspection Number 17351 Station Unit N/A N/A SUMMARY OF INSPECTION 0 40 Passed codes NEXT STEPS 0 13 Failed codes 25 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/21/2025 @ 13:12 $80 annual inspection fee BRAD BALDWIN - 08/21/2025 @ 13:17 Kitchen hood suppression due for service on 914125 BRAD BALDWIN - 08/21/2025 @ 13:25 Commercial kitchen exhaust hood cleaning due 12/10/25 BRAD BALDWIN - 08/21/2025 @ 13:48 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224 Reinspection Date 09/12/2025 BRAD BALDWIN - 08121/2025 @ 13:49 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/21/2025 @ 13:49 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Thomas Hernadus Date: BRAD BALDWIN 08/2112025 GENERATED ON 8/21/25, 1:52 PM 1 OF 8 CHECKLISTS Means of Egress Status Code Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Additional Codes Status Code Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: West exit door near basement stairs Comments: Repair or replace door to open with less than 15lbs of force. Door did not open today. Description Comments: Permit issued for outlet installed by Newton Electric without inspection. Contractor must obtain inspection. Location: Basement Comments: Secure CO2 compressed gas cylinders with chain to avoid tip over. GENERATED ON 8/21/25, 1:52 PM 2 OF 8 Emergency Equipment Status Code Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Location: Dining area, Northeast exit. Comments: Emergency egress lights on exit sign very dim during testing, repair or replace. GENERATED ON 8/21/25, 1:52 PM 3 OF 8 Electrical Safety Status Code Fail Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multipiug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multipiug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Description Location: Kitchen above dishwasher Comments: Damaged junction box cover exposing wires shall be replaced. Location: Kitchen exhaust hood above cooktop Comments: Switch cover plate loose to box exposing wires, install cover back on box. Location: Dining (east side) above TV Comments: Remove multi -plug adapter, may replace with properly mounted or supported power strip with manual reset. Adding outlet would require permit and inspection obtained by licensed contractor. Location: Patron waiting area above Coors Light week sign. Comments: Remove multi -plug adapter, may replace with properly mounted or supported power strip with manual reset. Adding outlet would require permit and inspection obtained by licensed contractor. GENERATED ON 8/21/25, 1:52 PM 4 OF 8 FF�ail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Kitchen near microwave Comments: Remove extension cord to microwave. Relocate microwave to plug directly to wall outlet or add outlet by licensed electrical contractor with obtaining permit and inspection. GENERATED ON 8/21/25, 1:52 PM 5 OF 8 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Status Code Fail 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSUIKECA C10. Location: Kitchen near 6 burner stove Comments: Remove white multi -plug extension cord, may replace with power strip with manual reset plugged to wall outlet. Description Location: Kitchen hood exhaust filters Comments: Clean grease filters. currently dripping grease. GENERATED ON 8/21/25, 1:52 PM 6 OF 8 Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Oto,c pilo Comments: Provide annual service to all fire extinguishers in building, currently due by August 2025. Location: Kitchen above chest freezer Comments: Annually serviced fire extinguisher shall me mounted to wall bracket where indicating by wall sign. GENERATED ON 8/21/25, 1:52 PM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 8/21/25, 1:52 PM 8 OF 8