Loading...
HomeMy WebLinkAbout3700 UNIVERSITY AVE• .s 0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/10/2025 10/15/2025 2026-00000123 $80.00 Customer #: 22164 HY-VEE GAS 3700 UNIVERSITY AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3700 UNIVERSITY AVE - 8-27-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22164 09/10/2025 10/15/2025 2026-00000123 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Hy-Vee Fast and Fresh - 3700 University AVE, BLDG 3700 University Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 08/27/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 15491 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 50 Passed codes NEXT STEPS 0 12 Faded codes 17 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/2812025 @ 12:41 $80 annual inspection fee BRAD BALDWIN - 08/28/2025 @ 12:42 Fire extinguishers due annually serviced March 2026 BRAD BALDWIN - 08/28/2025 @ 13:19 Kitchen hood exhaust cleaning due 9130125. Kitchen hood suppression system due 10/29/25. BRAD BALDWIN - 08/28/2025 @ 13:45 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224 Reinspection Date 09/19/2025 BRAD BALDWIN - 08/28/2025 @ 13:45 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/28/2025 @ 13:46 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Jacob Dryer (2025) Date: BRAD BALDWIN 08/28/2025 GENERATED ON 8/28/25, 1:48 PM 1 OF 9 CHECKLISTS GENERATED ON 8/28/25, 1:48 PM 2 OF 9 Additional Codes Status Code Fail Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Description Location: Grease trap Comments: Obtain inspection of "grease trap repair", permit obtained by Bergen Plumbing & Heating without inspection. Location: East side exterior Comments: Secure compressed gas cylinders with chain to avoid tip over. GENERATED ON 8/28/25, 1:48 PM 3 OF 9 Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures Al! electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Emergency Equipment Status Code Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1, Location: Caribou Coffee - under counter Comments: Secure compressed gas cylinders with chain to wall or secure item avoid tip over. Location: Storage area above CO2 tank Comments: Pump plugged into power strip shall be removed. Pump shall be plugged directly to wall outlet per manufacturers requirements. Descr p Location: Caribou Coffee - above merchandise wall Comments: Repair or replace egress lighting that failed to illuminate during test. GENERATED ON 8/28/25, 1:48 PM 4 OF 9 Electrical Safety Status Code Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Beer walk-in fridge Comments: Repair loose junction box cover Location: East exterior outlet Comments: Provide proper cover to outlet. GENERATED ON 8/28/25, 1:48 PM 5 OF 9 Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Northwest exterior outlet near drive-thru Comments: Provide missing outlet cover. Location: Caribou Coffee electric panel Comments: Remove pallet and all storage on floor in front of panel within 36", maintain clear path at all times for firefighters. GENERATED ON 8/28/25, 1:48 PM 6 OF 9 Fail Fail c 603.4.1 - Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Caribou Coffee electric panel Comments: Provide permanent sign (red with white lettering, minimum 4" tall letters), reading "Electric Panel". Laminated paper will not be accepted. Location: ATM Comments: Remove multi -plug adapter used for ATM, may replace with power strip with manual reset properly supported or mounted to wall plugged to wall outlet. GENERATFD ON 8/28/25, 1:48 PM 7 OF 9 Portable Fire Extingusihers Status Code Fail 906.8 - Cabinets. Cabinets used to house portable fire extinguishers shall not be locked. Exceptions: 1.Where portable fire extinguishers subject to malicious use or damage are provided with a means of ready access. 2.In Group 1-3 occupancies and in mental health areas in Group 1-2 occupancies, access to portable fire extinguishers shall be permitted to be locked or to be located in staff locations provided that the staff has keys. Description Location: Front of building Comments: Repair or replace missing glass to extinguisher cabinet. GENERATED ON 8/2825, 1:48 PM 8 OF 9 Statement of Fees FEE invoice Date Inspection Fee NIA $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A NIA GENERATED ON 8/28/25, 1:48 PM 9 OF 9