COMMERCIAL INSPECTION - 1425 E SAN MARNAN - 8-29-25
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 1
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
14982
09/10/2025
10/15/2025
2026-00000126
$100.00
Less Prepavnient
Total Due —)
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue \'
Inspection Report \v
Longhorn Steakhouse - 1425 E San Marnan DR, BLDG 1425 E San Marnan Dr,
Waterloo IA 50702
INSPECTION DETAILS
425 E. 3rd Street
Inspection Date Inspection Type Inspection Number
08/29/2025 Annual Inspection (1Yr)_J REINSPECTION) 14817-R2
Lead Inspector
BRAD BALDWIN
Other inspectors
NIA
Shift Station Unit
N/A NIA N/A
SUMMARY OF INSPECTION
) 0
Passed codes
NEXT STEPS
0 2
Resolved violations
0 3
Failed codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 0812912025 @ 15:00
$100 re -inspection fee, failure to complete corrections as of 8129/25.
BRAD BALDWIN - 08/29/2025 @ 15:07
Corrected on site (8/29/25): Caroline cleaned dust of kitchen sprinkler heads.
BRAD BALDWIN - 08/08/2025 @ 13:43
$80 annual inspection fee
BRAD BALDWIN - 08/08/2025 @ 13:43
Fire extinguishers due serviced October 2025.
BRAD BALDWIN - 08/0812025 @ 13:43
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
09/22/2025
BRAD BALDWIN - 08108/2025 @ 13:43
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 08/08/2025 @ 13:43
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. """**Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 8/29/25, 3:09 PM 1 OF 3
Caroline (2025) Mgr
CHECKLISTS
Reinspection
`Status Code
Fail
Fail
Fail
Date:
BRAD BALDWIN 08129/2025
1010.1.3 - Door opening force Forces to unlatch and open
doors.
The force for pushing or pulling open interior swinging
egress doors, other than fire doors, shall not exceed 5
pounds (22 N). These forces do not apply to the force
required to retract latch bolts or disengage other devices that
hold the door in a closed position. For other swinging doors,
as well as sliding and folding doors, the door latch shall
release when subjected to a 15-pound (67 N) force. The door
shall be set in motion when subjected to a 30-pound (133 N)
force. The door shall swing to a full -open position when
subjected to a 15-pound (67 N) force. The forces to unlatch
doors shall comply with the following: 1.Where door
hardware operates by push or pull, the operational force to
unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where
door hardware operates by rotation, the operational force to
unlatch the door shall not exceed 28 inch -pounds (315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated, other than doors required to be fire rated, the force
for pushing or pulling open the door shall not exceed 5
pounds (22 N). 2.For other swinging doors, sliding doors or
folding doors, and doors required to be fire rated, the door
shall require not more than a 30-pound (133 N) force to be set
in motion and shall move to a full -open position when
subjected to not more than a 15-pound (67 N) force.
2015 IFC - Fire alarm testing and maintenance
Is the fire alarm system powered, operational and displaying
normal operation (no troubles, supervisory, or alarms)?
5.2.1- Annual sprinkler system inspection
Sprinklers shall be inspected at least annually by licensed
contractor
Description
Location: Sprinkler riser room
Comments: Repair or replace door to allow door to open with less
than 15 lbs of force. Replacement of door would require permit
obtained with City Building Dept.
Additional comments: No progress on repairs made today
Location: Fire Alarm
Comments: Provide correction and report to 1 deficiency remaining
on Compliance Engine.
Additional comments: Phone call with Johnson Controls on report #
6601573 today, no record of repairs made or visit back since.
Location: Sprinkler system
Comments: Provide correction and report to 1 deficiency remaining
on Compliance Engine.
Additional comments: Phone call with Tri-State Fire Controls on
report # 6460635 today, no record of repairs made or visit back since.
Caroline said (Johnson Controls) has made this repair, contractor
must upload report of repair to Compliance Engine.