Loading...
HomeMy WebLinkAbout1425 E SAN MARNAN AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/10/2025 10/15/2025 2026-00000126 $100.00 Customer #: 14982 LONGHORN STEAKHOUSE #5374 1425 E SAN MARNAN AV WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1425 E SAN MARNAN - 8-29-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 14982 09/10/2025 10/15/2025 2026-00000126 $100.00 Less Prepavnient Total Due —) City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue \' Inspection Report \v Longhorn Steakhouse - 1425 E San Marnan DR, BLDG 1425 E San Marnan Dr, Waterloo IA 50702 INSPECTION DETAILS 425 E. 3rd Street Inspection Date Inspection Type Inspection Number 08/29/2025 Annual Inspection (1Yr)_J REINSPECTION) 14817-R2 Lead Inspector BRAD BALDWIN Other inspectors NIA Shift Station Unit N/A NIA N/A SUMMARY OF INSPECTION ) 0 Passed codes NEXT STEPS 0 2 Resolved violations 0 3 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 0812912025 @ 15:00 $100 re -inspection fee, failure to complete corrections as of 8129/25. BRAD BALDWIN - 08/29/2025 @ 15:07 Corrected on site (8/29/25): Caroline cleaned dust of kitchen sprinkler heads. BRAD BALDWIN - 08/08/2025 @ 13:43 $80 annual inspection fee BRAD BALDWIN - 08/08/2025 @ 13:43 Fire extinguishers due serviced October 2025. BRAD BALDWIN - 08/0812025 @ 13:43 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 09/22/2025 BRAD BALDWIN - 08108/2025 @ 13:43 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/08/2025 @ 13:43 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. """**Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 8/29/25, 3:09 PM 1 OF 3 Caroline (2025) Mgr CHECKLISTS Reinspection `Status Code Fail Fail Fail Date: BRAD BALDWIN 08129/2025 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. 2015 IFC - Fire alarm testing and maintenance Is the fire alarm system powered, operational and displaying normal operation (no troubles, supervisory, or alarms)? 5.2.1- Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor Description Location: Sprinkler riser room Comments: Repair or replace door to allow door to open with less than 15 lbs of force. Replacement of door would require permit obtained with City Building Dept. Additional comments: No progress on repairs made today Location: Fire Alarm Comments: Provide correction and report to 1 deficiency remaining on Compliance Engine. Additional comments: Phone call with Johnson Controls on report # 6601573 today, no record of repairs made or visit back since. Location: Sprinkler system Comments: Provide correction and report to 1 deficiency remaining on Compliance Engine. Additional comments: Phone call with Tri-State Fire Controls on report # 6460635 today, no record of repairs made or visit back since. Caroline said (Johnson Controls) has made this repair, contractor must upload report of repair to Compliance Engine. GENERATED ON 8/29/25, 3:09 PM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number NIA Check Number NIA Transaction Number N/A GENERATED ON 8/29/25, 3:09 PM 3 OF 3