Loading...
HomeMy WebLinkAbout1816 WILLISTON AVE (2)INVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/10/2025 10/15/2025 2026-00000140 $80.00 Customer #: 12189 BALKAN GRILL 926 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1816-1820 WILLISTON AVE - 9-3-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 12189 09/10/2025 10/15/2025 2026-00000140 Less Prepayment Total Due —> City of Waterloo $80.00 $0.00 S80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Balkan Cafe - 1816-1820 Williston AVE, BLDG 1816 Williston Ave - STE 1816, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 09103/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other inspectors N/A Shift NIA 425 E. 3rd Street Inspection Number 3711 Station Unit N/A NIA SUMMARY OF INSPECTION 0 41 Passed codes NEXT STEPS 0 15 Failed codes 24 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/03/2025 @ 14:57 $80 annual inspection fee BRAD BALDWIN - 09/03/2025 @ 15:00 Fire extinguishers due annually serviced by April 2026. BRAD BALDWIN - 09/11/2025 @ 06:56 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 09111/2025 @ 06:56 Reinspection Date 10/10/2025 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Q7 Irma Duric (2025) Date: BRAD BALDWIN 09/11/2025 CHECKLISTS GENERATED ON 9/11/25, 7:24 AM 1 OF 5 General Housekeeping Swtos Code 304.3.1 - Spontaneous ignition. Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. Contents of such containers shall be removed and disposed of daily. Additional Codes Status Code Fail V Fail Fail 3107.12.1 - Installation. Heating or cooking equipment, tanks, piping, hoses, fittings, valves, tubing and other related components shall be installed as specified in the International Fuel Gas Code and the International Mechanical Code , and shall be approved by the fire code official. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. ntrtlon Location: Kitchen Comments: Provide listed container for oily rag disposal. See attachment. De SCriiniun Location: Auxiliary exhaust fan Comments: Provide documents for proper installation of fan. Location: Pizza warmer behind check-out Comments: Appliance shall be plugged directly to wall outlet, currently plugged to power strip. Power strips allowed for light duty electric only. If adding outlet, licensed electrical contractor must obtain permit and inspection. Location: Coffee maker behind check-out Comments: Appliance shall be plugged directly to wall outlet, currently plugged to power strip. Power strips allowed for light duty electric only. If adding outlet, licensed electrical contractor must obtain permit and inspection. GENERATED ON 9/11/25, 7:24 AM 2 OF 5 Electrical Safety Status Code Fail 0 Fail Fail 0 Fail Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Description Location: Kitchen salad fridge Comments: Remove fridge from power strip, plug directly to wall outlet. Power strips allowed for Tight duty electric only. Location: Soffit lighting above outdoor seating Comments: Provide bulb for open light socket. Location: Outlet under small fryer Comments: Remove yellow 3-plug adapter. May use properly supported or mounted power strip with manual reset plugged directly to wall outlet for light duty electric only. Location: Checkout stand Comments: Power strip plugged to extension cord shall be corrected. Properly mounted or supported power strips with manual reset shall be plugged directly to wall outlet, for light duty electric only. If adding outlet, licensed electrical contractor must obtain permit and inspections. Location: Under pizza warmer Comments: Mount power strip to cabinet wall or support on shelf to avoid hanging by wires. Location: Bathroom hallway closet Comments: Remove extension cord to chest freezer, relocate freezer to plug directly to wall outlet or add outlet. Adding outlet requires licensed electrical contractor to obtain permit and inspections. GENERATED ON 9/11/25, 7:24 AM 3 OF 5 Fail Fail Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Stdtus Code Fail 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSIIIKECA C10. Location: Bathroom hallway closet Comments: Green extension cord allowed for temporary use only. Currently plugged to kitchen freezer. Location: Checkout stand Comments: Remove yellow extension cord plugged to power strip, extension cords only for temporary use. Location: Near large kitchen freezer Comments: Mixer and chest freezer appliances shall be plugged directly to wall outlets, remove extension cords. Location: Auxiliary exhaust fan Comments: Remove extension cord to exhaust system, approved for temporary use only. Description Location: Kitchen hood exhaust filters. Comments: Close gaps in grease filters by replacing missing filters. Filters not in place cause more grease in ductwork and on cables for fire supression. GENERATED ON 9/11/25, 7:24 AM 4 OF 5 4 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 invoice Number NIA Date Paid Amount Paid Check Number Transaction Number N/A NIA GENERATED ON 9/11/25, 7:24 AM 5 OF 5