Loading...
HomeMy WebLinkAbout210 E TOWER PARKINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/17/2025 11/25/2025 2026-00000162 $200.00 Customer #: 10758 SAM'S CLUB #6514 210 E TOWER PARK DR WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 210 E TOWER PARK - 9-18-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION 3 Total Price $200.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10758 10/17/2025 11/25/2025 2026-00000162 $200.00 Less Prepayment Total Due —> City of Waterloo $0.00 $200.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Sam's Club - 210 E Tower Park DR, BLDG 210 E Tower Park Dr, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type 09/18/2025 Annual Inspection (1Yr) ( REINSPECTION Lead Inspector BRAD BALDWIN Other Inspectors NIA 425 E. 3rd Street Inspection Number 12174-R8 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 00 Passed codes NEXT STEPS 0J 1 Resolved violations 0 4 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES Reinspection Date 10/10/2025 BRAD BALDWIN - 09/1812025 @ 15:10 $200 re -inspection fee, failure to correct any deficiencies as of 8128/25. Re -inspection fee's will continue until corrections are completed. BRAD BALDWIN - 08/2812025 @ 08:55 Provide correctins to avoid re -inspection fees BRAD BALDWIN - 08128/2025 @ 08:55 annual inspection $600 BRAD BALDWIN - 08/28/2025 @ 08:55 Fire door drop test 5/13/24 BRAD BALDWIN - 08/28/2025 @ 08:55 Fire pump maintenance Elite 2120/24 BRAD BALDWIN - 08/28/2025 @ 08:55 Fire Alarm inspection due 3/19/25 BRAD BALDWIN - 08/28/2025 @ 08:55 hood fire suppression due 3/30/25 BRAD BALDWIN - 08/28/2025 @ 08:55 Provide corrections to avoid $100 re -inspection fee. BRAD BALDWIN - 08/28/2025 @ 08:55 No fee today because some work completed. Fees will apply if all corrections not completed. BRAD BALDWIN - 08/28/2025 @ 08:55 Failure to correct violations may result in re -inspections fees GENERATED ON 9/19/25, 7!38 AM 1 OF 4 BRAD BALDWIN - 08/28/2025 @ 08:55 RE-inspeciton fee $100 BRAD BALDWIN - 08/2812025 @ 08:55 $150 re -inspection fee, failure to correct violations as of 7117125. BRAD BALDWIN - 08/28/2025 @ 08:55 $200 re -inspection fee for failure to correct violations. BRAD BALDWIN - 09119/2025 @ 07:36 $200 re -inspection fee, failure to correct any deficiencies as of 9/19125. Re -inspection fee's will continue until corrections are completed. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection _Ea Josh Marx - Club Manager Date: BRAD BALDWIN 09/1812025 CHECKLISTS GENERATED ON 9/19/25, 7..38 AM 2 OF 4 FReinspection tatuu Fail Fail Fail Code 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. 507.5.3 - Private fire service mains and water tanks. Private fire service mains and water tanks shall be periodically inspected, tested and maintained in accordance with NFPA 25 at the following intervals: 1.Private fire hydrants of all types: Inspection annually and after each operation; flow test and maintenance annually. 2.Fire service main piping: Inspection of exposed, annually; flow test every 5 years. 3.Fire service main piping strainers: Inspection and maintenance after each use. Records of inspections, testing and maintenance shall be maintained. 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Additional Codes Status Code Fail 901.6 - Inspection, testing and maintenance. 0 Fire detection and alarm systems, emergency alarm systems, gas detection systems, fire -extinguishing systems, mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . Description Location: Exit door by eco lab # 7 and case of shell oil Comments: Repair exit door. Exit door must unlatch and swing to full open with less than 15# force. Door would not open at all today. If replaced obtain permits and inspectcions. Additional comments: No permit as of 9/19/25 Location: Private fire hydrant Comments: Service for hydrant now 28 days past due as of 6/26/25. Private hydrants need to be inspected by licensed contractor and report uploaded to Compliance engine by contractor Additional comments: 2 deficiencies still remain on 9/19125 Location: Kitchen hood exhaust system Comments: Provide quarterly hood exhaust cleaning with report uploaded by contractor to Compliance Engine. Currently 15 days past due as of 8/7125. Additional comments: 58 days past due as of 9/19/25 Description Location: Fire sprinkler system Comments: Provide report of repair to deficiency noted in report # 7847909 on 8115/25. 2" drain line is leaking GENERATED ON 9/19/25, 7•38 AM 3 OF 4 Statement of Fees FEE Invoice Date NIA Invoice Number N/A Inspection Fee $200.00 Date Paid Amount Paid Check Number N/A Transaction Number NIA GENERATED ON 9/19/25, 7:38 AM 4 OF 4