Loading...
HomeMy WebLinkAbout518 JEFFERSONINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/17/2025 11/20/2025 2026-00000143 $80.00 Customer #: 24632 Carpenters Diner 518 Jefferson 3046 Bethel WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 518 JEFFERSON - 9-12-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DLJE DATE INVOICE # CHARGES 24632 10/17/2025 11/20/2025 2026-00000143 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Carpenter's Diner - 518 Jefferson ST, BLDG 518 Jefferson St, Waterloo IA 50701 INSPECTION DETAILS inspection Date 09/12/2025 Lead inspector BRAD BALDWIN inspection Type Annual Inspection (1Yr) Other Inspectors NIA b3Z 425 E. 3rd Street Inspection Number 14818 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION C48 02 ®23 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/12/2025 @ 13:55 $80 annual inspection fee BRAD BALDWIN - 0911212025 @ 13:56 Kitchen hood exhaust cleaning due 10/14/25 BRAD BALDWIN - 09/12/2025 @ 13:57 Kitchen hood suppression system due 10117/25 BRAD BALDWIN - 09/12/2025 @ 13:59 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 10/0912025 BRAD BALDWIN - 09/12/2025 @ 13:59 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Matthew Carpenter Date: BRAD BALDWIN 09112/2025 CHECKLISTS GENERATED ON 9/12/25, 2:02 PM 1 OF 3 Emergency Equipment Stet, ,{s Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Portable Fire Extingusihers Status Fail Location: Rear door Comments: Repair or replace exit sign that failed to illuminate during test. Code Description 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Comments: Provide annual service to all fire extinguishers. Picture of service tag may be emailed to inspector. GENERATED ON 9/12/25, 2:02 PM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA N/A GENERATED ON 9/12/25, 2:02 PM 3 OF 3