Loading...
HomeMy WebLinkAbout135 E RIDGEWAY AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/17/2025 11/25/2025 2026-00000159 $80.00 Customer #: 24479 KWIK STAR - E RIDGEWAY AVE 1626 OAK ST LA CROSSE , WI 54602 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 135 E RIDGEWAY - 9-19-25 Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 24479 BILLING DATE 10/17/2025 DUE DATE 11/25/2025 INVOICE # 2026-00000159 CHARGES Less Prepayment Total Due — City of Waterloo $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Kwik Star - 135 E Ridgeway AVE, BLDG 135 E Ridgeway Avenue, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 09119/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other inspecto N/A 425 E. 3rd Street Inspection Number 15068 Shill Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 49 Passed codes NEXT STEPS 0 4 Failed codes 0 21 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/19/2025 @ 14:28 Corrected during inspection: Removed garbage cart from exit path of rear storage room exit. Maintain clear path at all times. BRAD BALDWIN - 09/19/2025 @ 15:42 Storage of gas snow blower Ok'd by Fire Marshall. Maintain less than 10 gallons of gasoline in blower. BRAD BALDWIN - 09/19/2025 @ 15:42 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 10/13/2025 BRAD BALDWIN - 09/19/2025 @ 15:42 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 09/19/2025 @ 15:42 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 09/19/2025 @ 15:44 $80 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Alicia 2025-store leader Date: BRAD BALDWIN 09/19/2025 GENERATED ON 9/19/25, 3:45 PM 1 OF 4 CHECKLISTS Additional Codes =satus Code Fail 504.1 - Required access. Exterior doors and openings required by this code or the International Building Code shall be maintained readily accessible for emergency access by the fire department. An approved access walkway leading from fire apparatus access roads to exterior openings shall be provided where required by the fire code official. Commercial Cooking Hood Suppression System Status Code Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Description Location: Back storage room Comments: Remove obstructions to roof access stairs, maintain clear path at all times. Description Location: Kitchen exhaust hood cleaning Comments: Exhaust system cleaning 14 days past due as of 9/19/25. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. GENERATED ON 9/19/25, 3:45 PM 2 OF 4 J Portable Fire Extingusihers Status Fail Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.6 - Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the Locations of extinguishers. Diy cnt for Comments: Provide annual service to all fire extinguishers. Multiple dates noted on extinguishers throughout building. Location: Back storage room Comments: Remove obstructions to extinguisher, maintain clear path of access at all times. GENERATED ON 9/19/25, 3:45 PM 3 OF 4 Statement of Fees FEE Invoice Date NIA Invoice Number NIA Inspection Fee $80.00 Date Paid Amount Paid Check Number NIA Transaction Number NIA GENERATED ON 9/19/25, 3:45 PM 4 OF 4