COMMERCIAL INSPECTION - 135 E RIDGEWAY - 9-19-25
Description
FOR BILLING INQUIRY: (319)291-4323
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
24479
BILLING DATE
10/17/2025
DUE DATE
11/25/2025
INVOICE #
2026-00000159
CHARGES
Less Prepayment
Total Due —
City of Waterloo
$80.00
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Kwik Star - 135 E Ridgeway AVE, BLDG 135 E Ridgeway Avenue, Waterloo IA 50701
INSPECTION DETAILS
Inspection Date
09119/2025
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other inspecto
N/A
425 E. 3rd Street
Inspection Number
15068
Shill Station Unit
NIA NIA N/A
SUMMARY OF INSPECTION
0 49
Passed codes
NEXT STEPS
0 4
Failed codes
0 21
NIA codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 09/19/2025 @ 14:28
Corrected during inspection: Removed garbage cart from exit path of rear storage room exit. Maintain clear path at all times.
BRAD BALDWIN - 09/19/2025 @ 15:42
Storage of gas snow blower Ok'd by Fire Marshall. Maintain less than 10 gallons of gasoline in blower.
BRAD BALDWIN - 09/19/2025 @ 15:42
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
10/13/2025
BRAD BALDWIN - 09/19/2025 @ 15:42
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 09/19/2025 @ 15:42
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 09/19/2025 @ 15:44
$80 annual inspection fee
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Alicia 2025-store leader Date: BRAD BALDWIN 09/19/2025
GENERATED ON 9/19/25, 3:45 PM
1 OF 4
CHECKLISTS
Additional Codes
=satus Code
Fail
504.1 - Required access.
Exterior doors and openings required by this code or the
International Building Code shall be maintained readily
accessible for emergency access by the fire department. An
approved access walkway leading from fire apparatus access
roads to exterior openings shall be provided where required
by the fire code official.
Commercial Cooking Hood Suppression System
Status Code
Fail
606.3.3 - Cleaning.
Hoods, grease -removal devices, fans, ducts and other
appurtenances shall be cleaned at intervals as required by
Sections 606.3.3.1 through 606.3.3.3.
Description
Location: Back storage room
Comments: Remove obstructions to roof access stairs, maintain
clear path at all times.
Description
Location: Kitchen exhaust hood cleaning
Comments: Exhaust system cleaning 14 days past due as of 9/19/25.
Provide cleaning and report to be uploaded to Compliance Engine
with any deficiencies corrected.
GENERATED ON 9/19/25, 3:45 PM
2 OF 4
J
Portable Fire Extingusihers
Status
Fail
Fail
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
906.6 - Unobstructed and unobscured.
Portable fire extinguishers shall not be obstructed or
obscured from view. In rooms or areas in which visual
obstruction cannot be completely avoided, means shall be
provided to indicate the Locations of extinguishers.
Diy cnt for
Comments: Provide annual service to all fire extinguishers. Multiple
dates noted on extinguishers throughout building.
Location: Back storage room
Comments: Remove obstructions to extinguisher, maintain clear path
of access at all times.
GENERATED ON 9/19/25, 3:45 PM
3 OF 4
Statement of Fees
FEE
Invoice Date
NIA
Invoice Number
NIA
Inspection Fee
$80.00
Date Paid Amount Paid
Check Number
NIA
Transaction Number
NIA
GENERATED ON 9/19/25, 3:45 PM
4 OF 4