Loading...
HomeMy WebLinkAbout2100-2102 LAFAYETTEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/17/2025 11/25/2025 2026-00000163 $80.00 Customer #: 13067 NEIGHBORHOOD MART 2100 LAFAYETTE ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2100-2102 LAFAYETTE - 10-1-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 13067 BILLING DATE 10/17/2025 DUE DATE 11/25/2025 INVOICE # 2026-00000163 CHARGES $80.00 Less Prepayment Total Due -� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Neighborhood Mart - 2100-2102 Lafayette AVE, BLDG 2100-2102 Lafayette Ave, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 10/01/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA Shift NIA 425 E. 3rd Street Inspection Number 15419 Station Unit NIA NIA SUMMARY OF INSPECTION 044 07 Passed codes Failed codes NEXT STEPS 0 24 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 10102/2025 @ 15:27 $80 annual inspection fee BRAD BALDWIN - 10/02/2025 @ 15:29 Fire extinguishers serviced in September 2025 BRAD BALDWIN - 10103/2025 @ 08:13 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 10/03/2025 @ 08:14 Reinspection Date 10/2412025 • Provide corrections to avoid progressive re -inspection fees beginning at $100. BeerlLiquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 10103/2025 @ 08:14 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Joyce Utsler CHECKLISTS No signature Report completed post inspection tt� Date: BRAD BALDWIN 10/03/2025 GENERATED ON 10/3/25, 8:33 AM 1 OF 5 Additional Codes Sta... CoCie Fail 1024.1 - Exit passagewaysGeneral. Exit passageways serving as an exit component in a means of egress system shall comply with the requirements of this section. An exit passageway shall not be used for any purpose other than as a means of egress and a circulation path. Description Location: 2nd exit hallway Comments: No storage in marked exit hallway allowed, remove storage. Would be approved, per City Building Official and occupancy load to remove exit sign, removing exit sign would then allow storage in hallway. GENERATED ON 10/3/25, 8:33 AM 2 OF 5 Electrical Safety S._A.t_ Code Fail Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Description Location: East exterior outlet Comments: Provide proper cover to outlet. Location: Back office Comments: Remove obstructions to clear path of access to electric panel. Location: Behind register counter Comments: Remove power strip plugged to other power strip, strips shall be plugged directly to wall outlet for light duty electric only. GENERATED ON 10/3/25, 8:33 AM 3 OF 5 Commercial Cooking Hood Suppression System Status Cod_ Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Portable Fire Extingusihers Fail Fail 906.8 - Cabinets. Cabinets used to house portable fire extinguishers shall not be locked. Exceptions: 1.Where portable fire extinguishers subject to malicious use or damage are provided with a means of ready access. 2.In Group 1-3 occupancies and in mental health areas in Group 1-2 occupancies, access to portable fire extinguishers shall be permitted to be locked or to be located in staff locations provided that the staff has keys. 906.8 - Cabinets. Cabinets used to house portable fire extinguishers shall not be locked. Exceptions: 1.Where portable fire extinguishers subject to malicious use or damage are provided with a means of ready access. 2.In Group 1-3 occupancies and in mental health areas in Group 1-2 occupancies, access to portable fire extinguishers shall be permitted to be locked or to be located in staff locations provided that the staff has keys. Description Location: Kitchen hood exhaust cleaning Comments: Exhaust system cleaning 9 days past due as of 1013/25. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. Description Location: Near gas pumps 3&4 Comments: Cabinet glass broken shall be replaced. Glass hammer missing shall be replaced. Location: Front of building Comments: Cabinet glass broken shall be replaced. Glass hammer missing shall be replaced. GENERATED ON 10/3/25, 8:33 AM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 10/3/25, 8:33 AM 5 OF 5