Loading...
HomeMy WebLinkAbout2126 KIMBALL AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/17/2025 11/25/2025 2026-00000158 $80.00 Customer #: 12084 HY-VEE WINE & SPIRITS 2126 KIMBALL AV WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2126 KIMBALL - 10-1-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 12084 10/17/2025 11/25/2025 2026-00000158 $80.00 Less Prepayment Total Due —* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. , Waterloo Fire Rescue Inspection Report Hy-Vee Wine & Spirits #1 - 2126 Kimball AVE, BLDG 2126 Kimball Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 10/01/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) i-ac Other Inspectors NIA 425 E. 3rd Street Inspection Number 14936 Shift Station Unit N/A NIA N/A SUMMARY OF INSPECTION 052 06 ®21 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN -10/02/2025 @ 13:36 $80 annual inspection fee BRAD BALDWIN - 10/02/2025 @ 13:37 Fire extinguishers annually serviced May 2025 by Hawkeye Fire & Safety. BRAD BALDWIN - 10/02/2025 @ 15:11 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 10/23/2025 BRAD BALDWIN - 10/02/2025 @ 15:11 • Provide corrections to avoid progressive re -inspection fees beginning at $100. BeerlLiquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 10102/2025 @ 15:11 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Jake Dryer 2025 CHECKLISTS Date: BRAD BALDWIN 10/02/2025 GENERATED ON 10/2/25, 3:14 PM 1 OF 6 O Fail Additional Codes Status Code Fail 603,1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Description Location: Back storage room microwave Comments: Microwave shall be plugged directly to wall outlet, remove from power strip. Location: Red Bull & Monster beverage fridge near cashier Comments: Appliances shall be plugged directly to wall outlet, currently plugged to power strip. Power strips approved for light duty electric only. GENERATED ON 10/2/25, 3:14 PM 2 OF 6 Faif Fail 6107.3 - Clearance to combustibles. Weeds, grass, brush, trash and other combustible materials shall be kept not less than 10 feet (3048 mm) from LP -gas tanks or containers. Location: Front of building LP cabinet Comments: Relocate firewood to maintain 10 feet of minimum distance from LP tank cabinet. 6109.12 - Location of storage outside of buildings. Storage outside of buildings of LP -gas containers awaiting use, resale or part of a cylinder exchange program shall be located in accordance with Table 6109.12. i?i RS l`r THURSDAY Location: Outdoor LP storage cabinet Comments: Provide documentation of maximum quantity (pounds) of LP allowed in storage cabinet. More than 2500 Ibs of LP storage requires 10 feet minimum distance from doorway or opening to the building. GENERATED ON 10/2/25, 3:14 PM 3 OF 6 Electrical Safety Status Code Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Back storage room Comments: Remove objects including fridge in front of electric panel, maintain path to as well as 36" in front of and 30" in width of clearance to panels at all times. GENERATED ON 10/2/25, 3:14 PM 4 OF 6 _Fire.r?osistant Construction Maintenance Status Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Back storage room door Comments: Carefully remove paint on fire rating tag on door without altering tag information. GENERATED ON 10/2/25, 3:14 PM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number N►A Check Number Transaction Number NIA NIA GENERATED ON 10/2/25, 3:14 PM 6 OF 6