Loading...
HomeMy WebLinkAbout3231 W 9TH STCustomer #: 3613 COLUMBUS HIGH SCHOOL 3231 W 9TH ST WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/17/2025 11/20/2025 2026-00000144 $235.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3231 W 9TH - 9-11-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 50,000 OCCUPANCY FEE Total Price $225.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 3613 10/17/2025 11/20/2025 2026-00000144 $235.00 Less Prepayment Total Due —> City of Waterloo $0.00 $235.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Columbus High School - 3231 W 9th ST, BLDG 3231 W 9th St, Waterloo IA 50702 INSPECTION DETAILS n.speotion Date 09/11/2025 ead inspector BRAD BALDWIN inspection Type Biennial Inspection (2yrs) Other inspector, BROCK WELIVER, JEREMIAH VANDYKE SUMMARY OF INSPECTION 425 E. 3rd Inspection Number 11568 Shift Station Unit NIA NIA NIA 064 09 02 Passed codas Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/12/2025 @ 13:49 Inspection fee= $225.00 BRAD BALDWIN - 09/1112025 @ 15:45 10/1012024 - (Annual) Kitchen Exhaust HARRIS CLEANING SERVICE. Reviewed Compliant BRAD BALDWIN - 09/11/2025 @ 15:46 2/14/25 - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Compliant BRAD BALDWIN - 09/11/2025 @ 15:47 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 09111.12025 @ 15:47 Fire extinguishers annually serviced July 2025. BRAD BALDWIN - 09/11/2025 @ 15:48 Reinspection Date 10/15/2025 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. ****"Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 09/12/2025 @ 08:53 Stage curtain fire treatment (2021). Next treatment due 2026. GENERATED ON 9/12/25, 1:49 PM 1 OF 6 :p e•a4a6LaSsee':vaia'ae'a'.e seam<.'aieG;P® i, Fire It d 1 C I K 11 s5. LLC '! R r/ I/ rj Y� i1 14 I/ FX FabricGuard Cc ttfleate of It e. imorlt ITV u ui.A u.1 M111:tia 13 BRAD BALDWIN - 09/12/2025 @ 13:22 IA Id I41 /a /4 '4 P4 /4 v4 r I4 ZZ>pspa® Corrected during 9/11/25 inspection: (1) Removed coffee pot from power strip in room #169. (2) Removed portable A1C from extension cord in media center. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection 1 Adam Plautz - Maintenance Date: BRAD BALDWIN 09/1212025 CHECKLISTS GENERATED ON 9/12/25, 1:49 PM 2 OF 6 Means of Egress Fail 0 Code 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Emergency Equipment Status Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Documentation Status i cnu Fail 403.4.1- First emergency evacuation drill. The first emergency evacuation drill of each school year shall be conducted within 10 days of the beginning of classes. Location: Shop garage Comments: Repair or replace north exit door that failed to push open with less than 15Ibs of force. Replacement of door will require building permit and inspection to be obtained. Oescription Comments: Provide documentation of testing all emergency egress lighting in building with repairs made if needed, including date and signature of person testing. Report may be emailed to inspector. Comments: Provide documentation of testing all exit signs in building with repairs made if needed, including date and signature of person testing. Report may be emailed to inspector. Description Comments: Provide record of first fire drill of school year. Fire drill shall be completed within first 10 days of each school year. GENERATED ON 9/12/25, 1:49 PM 3 OF 6 Additional Codes Status Code Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 610.1,2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer&#039;s operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Electrical Safety Status Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Fire Resistant Construction Maintenance Status Cade Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Description Location: Shop garage Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: 3 clothes dryers Comments: Provide documentation of clothes dryer vents cleaned from the appliance to the exterior of the building. Report shall be signed and dated and may be emailed to inspector. Description Location: Room # 222 Comments: Properly support power strip above microwave or mount to wall surface to avoid hanging by wires Description Location: Double hallway doors outside of gymnasium Comments: Repair door to fully close, currently hitting frame and fails to shut completely. GENERATED ON 9/12/25, 1:49 PM 4 OF 6 Portable Fire Extingusihers stales Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Room #229 Comments: Provide annual service to fire extinguisher, currently past due. GENERATED ON 9/12/25, 1:49 PM 5 OF 6 Statement of Fees FEE Invoice Date NIA Invoice Number NIA Inspection Fee $225.00 Date Paid Amount Paid Check Number NIA Transaction Number NIA GENERATED ON 9/12/25, 1:49 PM 6 OF 6