Loading...
HomeMy WebLinkAbout201 RATH STisa 55. ii fib INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/29/2025 08/05/2025 2026-00000051 $80.00 Customer #: 24755 ROME'S PLACE 201 RATH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 201 RATH ST - 7-24-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24755 07/29/2025 08/05/2025 2026-00000051 $80.00 Less Prepayment Total Due — City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Rome's Place - 201 Rath ST, BLDG 201 Rath St, Waterloo IA 50703 INSPECTION DETAILS inspection Date 07124/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 17339 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 45 Passed codes NEXT STEPS Q 9 Failed cones Q 24 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07/24/2025 @ 14:44 $80 annual inspection fee BRAD BALDWIN - 0712412025 @ 14:44 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 08/15/2025 BRAD BALDWIN - 07/24/2025 @ 14:45 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07124/2025 @ 14:45 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 07/24/2025 @ 14:51 Fire extinguishers due annually serviced May 2026 SIGNATURES Contact signature Inspector signature No signature Report cornpleted post inspection Rome Mabry (2025) Date: BRAD BALDWIN 07/2412025 CHECKLISTS GENERATED ON 7/24/25. 3:28 P51 1 OF 7 Emergency Equipment Status Code Fail l^J 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. General Housekeeping Statue Code Fail 305.1 - Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Description Location: Exit door near bar Comments: Repair sign that failed to illuminate during testing. 2nd Exit is already provided, would approve sign to be removed with wires properly capped and in electric box or appropriate cover installed over sign. Description Location: Bar water heater Comments: Remove combustible material and objects from water heater. GENERATED ON 7/24/25, 3:28 PM 2 OF 7 Additional Codes Status Code Description Fail 5303.5.3 - Securing compressed gas containers, cylinders Qand tanks. Location: Office CO2 tank Fail Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 606.1 - General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code . Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: Kitchen 4 burner range Comments: Kitchen exhaust hood shall overhang range by 6", move required covered cooking equipment to maintain under hood. GENERATED ON 7/24/25, 3:28 PM 3 OF 7 Electrical Safety Status Code Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 1)escriptiOn Location: Behind bar registers Comments: Power strip shall be plugged directly to wall outlet, remove from other power strip. GENERATED ON 7/24/25, 3:28 PM 4 OF 7 Fail Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Location: Near bar mini -fridge Comments: Power strip shall be plugged directly to wall outlet, remove from other power strip. Location: DJ Booth Comments: Power strip shall be plugged directly to wall outlet, remove from other power strip. Location: Office Comments: Power strip shall be plugged directly to wall outlet, remove from extension cord. GENERATED ON 7/24/25, 3:28 PM 5 OF 7 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location.. Near bar mini -fridge Comments: Remove green extension cord in use. GENERATED ON 7/24/25, 3:28 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 7/24/25, 3:28 PM 7 OF 7