COMMERCIAL INSPECTION - 926 LA PORTE RD - 7-22-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24594
07/29/2025
08/05/2025
2026-00000050
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program.if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
M&J Caribbean Bar Restaurant - 926 La Porte RD, BLDG 924 La Porte RD, Waterloo
IA 50701
INSPECTION DETAILS
Inspection Date
35
Lead Inspector
BRAD BALDWIN
Other Inspectors
N/A
Inspection Type
Annual Inspection (1Yr)
425 E. 3rd Street
Inspection Number
16112
Shift Station Unit
N/A NIA N/A
SUMMARY OF INSPECTION
45
Passed codes
NEXT STEPS
0 10
Failed codes
22
NIA codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 07/22/2025 @ 10:35
$80 annual inspection fee
Reinspection Date
08/14/2025
BRAD BALDWIN - 07/22/2025 @ 13:36
Liquor noted in building on 7/22125. Per City Clerk, valid liquor license is not obtained. All liquor shall be removed from business till liquor license has
been obtained.
BRAG BALDWIN - 07/22/2025 @ 13:37
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 07/22/2025 @ 13:38
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 07122/2025 @ 13:44
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
John Alesse-2025
CHECKLISTS
GENERATED ON 7/22/25, 1:50 PM
Date:
BRAD BALDWIN 07/22/2025
1 OF 7
Emergency Equipment
Status Code
Fail
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
Additional Codes
Status Code
Fail
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
on
Location: Front entry
Comments: Repair or replace exit sign that failed to illuminate during
testing.
Description
Location: Between seating & dining area
Comments: Remove all cords altered, spliced to make speaker/audio
wires.
GENERATED ON 7/22/25, 1:50 PM
2 OF 7
Electrical Safety
Status Code
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Descry flon
Location: Between seating & dining
Comments: Remove cords running across walkway susceptible to
damage or creating potential trip hazards.
GENERATED ON 7/22/25, 1:50 PM
3 OF 7
Fail
0
Fail
0
Fail
0
603.5 - Relocatable power taps and current taps.Multiplug
adapters.
Multiplug adapters, such as cube adapters, unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Location: Above couches, near TV
Comments: Remove current power strip from use. Power strips with
manual reset shall be properly mounted to solid surface or properly
supported on shelf.
Location: Behind couch
Comments: Remove green multi -plug extension cord.
Location: Behind arcade games
Comments: Remove extension cords from use. Provide power strip
with manual reset plugged directly to wall outlet or provide install
new outlet to power machines. Adding outlet will require permit and
inspections obtained.
Location: Office
Comments: Remove green multi -plug extension cord
GENERATED ON 7/22/25, 1:50 PM
4 OF 7
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Location: Freezer near office
Comments: Remove extension cord in use. Freezer shall be directly
plugged to wall outlet.
GENERATED ON 7/22/25, 1:50 PM 5 OF 7
Portable Fire Extingusihers
Status Code
Fail
Fail
J
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group I-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
906.7 - Hangers and brackets.
Hand-held portable fire extinguishers, not housed in cabinets,
shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the
mounting surface in accordance with the manufacturer's
installation instructions.
Description
Location: All fire extinguishers
Comments: Provide annual service to extinguishers , due by July
2025.
Location: Bar
Comments: Extinguisher sitting on bar. Properly hang extinguisher
on wall bracket within 4" to 5' from floor
GENERATED ON 7/22/25, 1:50 PM
6 OF 7