Loading...
HomeMy WebLinkAbout926 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/29/2025 08/05/2025 2026-00000050 $80.00 Customer #: 24594 M&J CARIBBEAN BAR RESTAURANT 926 LA PORTE RD WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 926 LA PORTE RD - 7-22-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24594 07/29/2025 08/05/2025 2026-00000050 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program.if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report M&J Caribbean Bar Restaurant - 926 La Porte RD, BLDG 924 La Porte RD, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 35 Lead Inspector BRAD BALDWIN Other Inspectors N/A Inspection Type Annual Inspection (1Yr) 425 E. 3rd Street Inspection Number 16112 Shift Station Unit N/A NIA N/A SUMMARY OF INSPECTION 45 Passed codes NEXT STEPS 0 10 Failed codes 22 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 07/22/2025 @ 10:35 $80 annual inspection fee Reinspection Date 08/14/2025 BRAD BALDWIN - 07/22/2025 @ 13:36 Liquor noted in building on 7/22125. Per City Clerk, valid liquor license is not obtained. All liquor shall be removed from business till liquor license has been obtained. BRAG BALDWIN - 07/22/2025 @ 13:37 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 07/22/2025 @ 13:38 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07122/2025 @ 13:44 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection John Alesse-2025 CHECKLISTS GENERATED ON 7/22/25, 1:50 PM Date: BRAD BALDWIN 07/22/2025 1 OF 7 Emergency Equipment Status Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Additional Codes Status Code Fail 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. on Location: Front entry Comments: Repair or replace exit sign that failed to illuminate during testing. Description Location: Between seating & dining area Comments: Remove all cords altered, spliced to make speaker/audio wires. GENERATED ON 7/22/25, 1:50 PM 2 OF 7 Electrical Safety Status Code Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Descry flon Location: Between seating & dining Comments: Remove cords running across walkway susceptible to damage or creating potential trip hazards. GENERATED ON 7/22/25, 1:50 PM 3 OF 7 Fail 0 Fail 0 Fail 0 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Above couches, near TV Comments: Remove current power strip from use. Power strips with manual reset shall be properly mounted to solid surface or properly supported on shelf. Location: Behind couch Comments: Remove green multi -plug extension cord. Location: Behind arcade games Comments: Remove extension cords from use. Provide power strip with manual reset plugged directly to wall outlet or provide install new outlet to power machines. Adding outlet will require permit and inspections obtained. Location: Office Comments: Remove green multi -plug extension cord GENERATED ON 7/22/25, 1:50 PM 4 OF 7 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Freezer near office Comments: Remove extension cord in use. Freezer shall be directly plugged to wall outlet. GENERATED ON 7/22/25, 1:50 PM 5 OF 7 Portable Fire Extingusihers Status Code Fail Fail J 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group I-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Description Location: All fire extinguishers Comments: Provide annual service to extinguishers , due by July 2025. Location: Bar Comments: Extinguisher sitting on bar. Properly hang extinguisher on wall bracket within 4" to 5' from floor GENERATED ON 7/22/25, 1:50 PM 6 OF 7 Statement of Fees FEE Invoice Date inspection Fee NIA $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 7/22/25, 1:50 PM 7 OF 7