Loading...
HomeMy WebLinkAbout1717 E SAN MARNAN DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/29/2025 08/05/2025 2026-00000049 $80.00 Customer #: 22592 KWIK STAR #229 1717 E SAN MARNAN AVE WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1717 E SAN MARNAN DR - 7-22-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22592 07/29/2025 08/05/2025 2026-00000049 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Kwik Star #229 - 1717 E San Marnan DR, BLDG 1717 E San Marnan Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Annual Inspection (1Yr) Lead Inspector BRAD BALDWIN Other Inspectors NIA E. 3rd Street Inspection Number 14493 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 49 Passed codes NEXT STEPS 0 6 Failed codes 0 19 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 0712212025 @ 14:47 $80 annual inspection fee BRAD BALDWIN - 07/2212025 @ 15:01 Fire extinguishers due annually serviced February 2026 BRAD BALDWIN - 07/22/2025 @ 15:38 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 08/14/2025 BRAD BALDWIN - 07/22/2025 @ 15:38 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 07/22/2025 @ 15:38 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Alicia (2025) District Manager Date: BRAD BALDWIN 07/22/2025 CHECKLISTS GENERATED ON 7/22/25, 3:42 PM 1 OF 5 General Housekeeping Status Code Fail 315.3.3 - Equipment rooms. Combustible material shall not be stored in boiler rooms, mechanical rooms, electrical equipment rooms or in fire command centers as specified in Section 508.1.5. Additional Codes Status Code Fail 504.1 - Required access. Exterior doors and openings required by this code or the International Building Code shall be maintained readily accessible for emergency access by the fire department. An approved access walkway leading from fire apparatus access roads to exterior openings shall be provided where required by the fire code official. Description Location: Basement mechanical area Comments: Remove combustible material from room. Maintain proper clearances to water heater. Description Location: Stairway to roof in back storage Comments: Maintain clear path to stairway, remove obstructions. Na sti (rot+tursga of steps GENERATED ON 7/22/25, 3:42 PM 2 OF 5 Electrical Safety Status Cade Fail Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Description Location: Back storage room at bottom of stairs to roof Comments: Properly install cover to outlet. Location: Behind food warming station Comments: Remove green extension cord. Location: Christmas lights around donut display Comments: Christmas lights allowed for maximum 90 days. Must be removed by 8-21-25. GENERATED ON 7/22/25, 3:42 PM 3 OF 5 Fire Resistant Construction Maintenance Status Code Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. tion Location: Ceiling near bathroom/office Comments: Replace missing ceiling tiles when work complete. GENERATED ON 7/22/25, 3:42 PM 4 OF 5 Po FEE Statement of Fees Invoice Date Inspection Fee NIA $80.00 Date Paid Amount Paid Invoice Number NIA Check Number NIA Transaction Number NIA GENERATED ON 7/22/25, 3:42 PM 5 OF 5