RENTAL FIRE INSPECTION - 224 SUNNYSIDE AVE - 02/10/2026
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION FEE 3RD
Total Price
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24845
02/11/2026
03/18/2026
2026-00000066
$250.00
Less Prepayment
Total Due —�
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
4Zb
248-5
Waterloo Fire Rescue
Inspection Report
KVA Holdings LLC - 224 Sunnyside AVE, Waterloo IA 50701-2542
INSPECTION DETAILS
425 E. 3rd Street
Inspection Date Inspection Type Inspection Number
02/10/2026 Rental Inspection REINSPECTION 17245-R7
Lead Inspector
BARRY STRATTON
Other Inspectors
NIA
Shift Station
NIA N/A
Unit
NIA
SUMMARY OF INSPECTION
Q o
Passed codes
NEXT STEPS
13
Failed codes
Please direct questions about your Inspection to:
BARRY STRATTON
barry.stratton@waterloo-ia.org, 3199611280
GENERAL NOTES
Reinspection Date
03/10/2026
BARRY STRATTON - 02/1012026 @ 09:54
304.10 Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be
maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads.
BARRY STRATTON - 02/1012026 @ 09:55
IPMC 604.3: 604.3 Electrical system hazards. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the
structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation, deterioration or
damage, or for similar reasons, the code official shall require the defects to be connected to eliminate the hazard.
BARRY STRATTON - 02/10/2026 @ 09:55
Some corrections have been completed on a re -inspection done today. Continue to make corrections to get rental unit completed.
BARRY STRATTON - 02/1012026 @ 09:55
Handrail to front deck stairs still not meeting code requirements.
SIGNATURES
Contact signature Inspector signature
PIA
KVA Holdings LLC
CHECKLISTS
02110/2026 BARRY STRATTON 02110/2026
GENERATED ON 2/10/26. 9:58 AM 1 OF 4
Reinspection
status. Code Description
Fail 1010.2 - Door operations.
Except as specifically permitted by this section, egress doors
shall be readily openable from the egress side without the
use of a key or special knowledge or effort.
Fail 603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Fail 906.1 - Where required.
Portable fire extinguishers shall be installed in all of the
following locations: 1.In new and existing Group A, B, E, F, H,
I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group
R-2 occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C. 2.In Group E
occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C. 3. In storage areas of Group
S occupancies where forklift, powered industrial truck or
powered cart operators are the primary occupants, fixed
extinguishers, as specified in NFPA 10, shall not be required
where in accordance with all of the following: 3.1. Use of
vehicle -mounted extinguishers shall be approved by the fire
code official. 3.2. Each vehicle shall be equipped with a 10-
pound, 40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use. 3.3. Not less than
two spare extinguishers of equal or greater rating shall be
available on -site to replace a discharged extinguisher. 3.4.
Vehicle operators shall be trained in the proper operation, use
and inspection of extinguishers. 3.5. Inspections of vehicle -
mounted extinguishers shall be performed daily. 2.Within 30
feet (9144 mm) distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1; 1-2, Condition 1; and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed. 4.On each floor of structures under
construction, except Group R-3 occupancies, in accordance
with Section 3316.1. 5.Where required by the sections
indicated in Table 906.1. 6.Special-hazard areas, including but
not limited to laboratories, computer rooms and generator
rooms, where required by the fire code official. Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
Fail 907.2.11 - Single- and multiple -station smoke alarms.
Listed single- and multiple -station smoke alarms complying
with UL 217 shall be installed in accordance with Sections
907.2.11.1 through 907.2.11.7 and NFPA 72.
Location: Back door
Location: Kitchen ceiling needs replaced, walls need drywall where
holes are, trim around doors, doors need to open and close (back
door) lights not working, globes needed on all lights.
Location: Need fire extinguisher installed.
Location: Need smoke detectors installed outside bedrooms and in
all bedrooms. Smoke detector needed in basement.
GENERATED ON 2/10/26, 9:58 AM
2 OF 4
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Fail
915.1- General.
Carbon monoxide detection shall be installed in new
buildings in accordance with Sections 915.1.1 through 915.6.
Carbon monoxide detection shall be installed in existing
buildings in accordance with Section 1103.9.
R1- Unsafe Structures
Is the structure found to be dangerous to the life, health,
property or safety of either the public or occupants of the
structure? (IPMC 108.1.1)
R2 - Unsafe Equipment
Was the presence of unsafe equipment noted during the
inspection? Equipment may include boilers, heating
equipment, elevator, moving stairways, electrical wiring, and
flammable liquid containers. (IPMC 108.1.2)
R5 - Exterior Structure
Is the exterior of the structure maintained in good repair,
structurally sound and sanitary state? (IPMC 304)
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
R6.A. - Interior Structure- Unsafe Conditions
Were any unsafe conditions noted during the interior
inspection?(IPMC 305.1.1)
R6.C. - Mechanical Eqiupment
Are mechanical appliances properly installed and maintained
in good working condition? (IPMC 603.1)
R6.D. - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a GFCI. Every bathroom shall
contain not less than one receptacle. Any new bathroom
receptacle shall have GFCI protection. All receptacles shall
have the appropriate faceplate cover. (IPMC 605.2)
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Location: Need CO detectors in stalled outside bedrooms
Location: Floors, walls, ceilings, basement stairs.
Location: Water heater, kitchen ceiling has water damage from
leaking plumbing. PEX not installed to meet code throughout
property.
Location: Front porch and front steps needs replaced. Need handrail
replaced on front stairs. Back stairs need replaced and need handrail
installed to meet code.
Additional comments: Handrails still do not meet code.
Location: Walls (holes) doors missing trim, holes in floors need
repaired, handrails to basement needed, electric covers missing,
back door needs to open and close, windows need to function and
have screens/locks tub missing handle for hot water side. Kitchen
cabinets need repaired and doors and drawer fronts in place.
Location: Electrical issues, plumbing issues, mold, water issues
Location: Water heater missing PT tube.
Location: Missing electrical covers
Location: PEX is leaking
GENERATED ON 2/10/26, 9:58 AM
3 OF 4
Statement of Fees