RENTAL FIRE INSPECTION - 132 LOBDELL RD - 02/11/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION FEE 3RD
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24800
02/16/2026
03/23/2026
2026-00000070
$250.00
Less Prepayment
Total Due —*
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Al5° vtoo
Waterloo Fire Rescue
Inspection Report
132 Lobdell RD, Waterloo IA 50701-1102
INSPECTION DETAILS
Inspection Date
02/1112026
Lead Inspector
BARRY STRATTON
Inspection Type
Rental Inspection REINSPECTION
Other Inspectors
NIA
425 E. 3rd Street
Inspection Number
16444-R8
Shift Station Unit
N/A N/A N/A
SUMMARY OF INSPECTION
0 0 0 4 0 6
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BARRY STRATTON
barry.stratton@waterloo-ia.org, 3199611280
GENERAL NOTES
Reinspection Date
03/11/2026
BARRY STRATTON - 02/12/2026 @ 06:52
Plumbing details: Several corrections noted during inspection, a licensed plumbing contractor shall obtain proper permits/inspections to correct any
deficiencies. Corrections include but may not be limited to: (1) Main floor bathroom sink drain, flexible drainage piping shall be replaced. (2) Water heater
installed without permit/inspection also missing approved PT tube. (3) Mechanical room sink drainage/vent piping installed not to plumbing code shall be
corrected. (4) Laundry drainagelvent piping installed not to plumbing code shall be corrected. S-trap in basement needs removed. Have licensed plumber
make corrections.
BARRY STRATTON - 02/12/2026 @ 06:53
Electrical details: Several corrections noted during inspection, a licensed electrical contractor shall obtain proper permitslinspections to correct any
deficiencies. Corrections include but may not be limited to: (1) Several open electrical boxes noted in basement without covers. Wires not landed in
boxes. (2) Lighting fixture noted in basement stoop unfixed, laying on shelf. (3) Electrical serving furnace, water heater & laundry installed without
permits/inspections. (4) Outlets/switches missing appropriate covers. (5) main floor SW bedroom, outlet below window failed tester due to "open
ground". (6) Loose wiring noted in basement shall be stapled. (7) Service mast tie down cable connected to chain, nailed to wood post shall be corrected.
BARRY STRATTON - 02/12/2026 @ 06:53
-Re-inspection date is as posted on the inspection report given, the rental unit's responsible personls shall reach out prior to set time of that re -
inspection. If all corrections are made before the scheduled inspection, you can call to set up an earlier re -inspection. Appropriate notices shall be given
to occupants of the unitls. Owner or owner's agent must be present during inspections. Failure to schedule a time on the date given or failure to keep the
inspection will result in a $100 fee. ""'Re inspection fees may be assessed for re -inspections. Re -inspection fees start at $50, then $150, and $250 for all
subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspection.
BARRY STRATTON - 02/12/2026 @ 06:53
No permits have been obtained for the required corrections noted from previous inspectors reports.
BARRY STRATTON - 02/12/2026 @ 06:54
Need current 2026 rental registration for listed address.
SIGNATURES
Contact signature Inspector signature
GENERATED ON 2/12/26, 6:58 AM 1 OF 5
Reinspection
Status
Fail
Fail
Fail
Fail
Colo
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
R6.C. - Mechanical Eqiupment
Are mechanical appliances properly installed and maintained
in good working condition? (IPMC 603.1)
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
Teaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Description
Location: Several electrical deficiencies
Comments: See notes for further details
Location: Furnace
Comments: Furnace installed without permit & inspection shall be
corrected. Licensed HVAC contractor shall obtain proper
permits/inspections to correct any deficiencies.
Additional comments: Furnace shall have electric to furnace installed
to code by licensed HVAC contractor. Electric box hanging by wires
and not encased in approved conduit.
Location: Main floor bathroom
Comments: Shower walls not water -tight shall be corrected.
Loose/flaking paint on wall surfaces shall be corrected.
Additional comments: PT Tube on water heater cut and material for
tube not approved material.
Location: Several plumbing issues
Comments: See notes for further details.
Additional comments: PT tube not on water heater. Abandoned
plumbing pipe shall be removed. Shower surround is not installed to
meet code and not water tight.