HomeMy WebLinkAbout1916 E MITCHELL AVEINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
02/16/2026
03/23/2026
2026-00000332
$200.00
Customer #: 24621
LOLO FOOD MARKET
1916 E MITCHELL AVE
WATERLOO, IA 50702
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION - 1916 E MITCHELL AVE -
02/13/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 3
$200.00
CUSTOMER # I BILLING DATE
24621 02/16/2026
DUE DATE
03/23/2026
INVOICE #
2026-00000332
CHARGES
$200.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$200.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
200 24 l01 t
Waterloo Fire Rescue
Inspection Report
Lolo Food Market - 1916 E Mitchell AVE, BLDG 1916 E Mitchell Ave, Waterloo IA
50702
INSPECTION DETAILS
Inspection Date
02/13/2026
Lead Inspector
BRAD BALDWIN
Inspection Type
Complaint (REINSPECTION
Other Inspectors
N/A
425 E. 3rd Street
Inspection Number
17660-R5
Shift Station Unit
N/A NIA N/A
SUMMARY OF INSPECTION
0 0 0 3
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
Reinspection Date
03►0612026
BRAD BALDWIN - 02/13/2026 @ 14:30
$200 re -inspection fee, failure to complete corrections as of 2/13126. Phone conversation with Yves today and discussed open violations.
BRAD BALDWIN - 01/16/2026 @ 14:20
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 01/16/2026 @ 14:20
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. "***"Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 01/16/2026 @ 14:20
Corrected during 10/15/25 inspection: Removed power strip daisy chained behind check-out counter.
BRAD BALDWIN - 01/16/2026 @ 14:20
All appliances manufactured to be plugged directly to wall receptacles shall be installed and maintained properly.
BRAD BALDWIN - 01116/2026 @ 14:20
$100 re -inspection fee, failure to complete corrections.
BRAD BALDWIN - 01/16/2026 @ 14:20
$150 re -inspection fee, failure to complete corrections
BRAD BALDWIN - 01/16/2026 @ 14:20
$200 re -inspection fee, failure to correct violations as of 1/16/26. Attempted to contact owner by phone to discuss inspection, no response.
SIGNATURES
Contact signature Inspector signature
GENERATED ON 2/13/26: 2:33 PM
1 OF 5
Reinspection
Status Code
Fail
Fail
603.5.2 - Application and usePower supply.
Relocatable power taps and current taps shall be directly
connected to a permanently installed receptacle. Exceptions:
1. Where approved for use in a Group A occupancy or in a
meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment. 2. Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Description
Location: Behind register stand
Comments: Remove power strip plugged to another power strip as
seen in picture attached. Power strips shall be plugged directly to
wall outlets at all times for light duty electric only.
Location: Behind register counter
Comments: Remove white multi -plug extension cord from power
strip.
GENERATED ON 2/13/26, 2:33 PM
3 OF 5
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $200.00
Invoice Number
NIA
Check Number Transaction Number
NIA NIA
GENERATED ON 2/13/26, 2:33 PM 5 OF 5