Loading...
HomeMy WebLinkAbout1215 FRANKLIN STO O • ,ri1/14+• O 0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/16/2026 03/23/2026 2026-00000328 $80.00 Customer #: 14785 MICHOACANA MEAT MARKET 1215 FRANKLIN ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1215 FRANKLIN ST - 02/10/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 14785 02/16/2026 03/23/2026 2026-00000328 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Michoacana Meat Market - 1215 Franklin ST, BLDG 1215 Franklin St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 02/10/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 16383 Shift Station Unit NIA N/A N/A SUMMARY OF INSPECTION 0 34 0 6 ®33 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 02/16/2026 @ 07:17 • $80 annual inspection fee BRAD BALDWIN - 02/16/2026 @ 07:29 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (45) - CeII: 319-230-1224 Reinspection Date 03/1112026 BRAD BALDWIN - 02/1612026 @ 07:29 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 02116/2026 @ 07:29 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Blanca Garcia Date: CHECKLISTS BRAD BALDWIN 02/16/2026 GENERATED ON 2/16/26, 7:33 AM 1 OF 6 Emergency Equipment Status Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required Toad for a duration of not less than 90 minutes. General Housekeeping Status Code Fail ® 305.1- Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Description Location: Back exit Comments: Repair or replace exit sign/egress light that failed to illuminate during test. Description Location: Mechanical room Comments: Remove storage on furnace, maintain 36" clearances at all times. GENERATED ON 2/16/26, 7:33 AM 2 OF 6 Electrical Safety Status Code Fail Q 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Freezer behind meat counter Comments: Provide plug to opening in box GENERATED ON 2/16/26, 7:33 AM 3 OF 6 Fail O 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical Location: Electric panel equipment shall be provided in accordance with Section Comments: Remove storage below panel and maintain clear path of 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or access at all times. less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). GENERATED ON 2/16/26, 7:33 AM 4 OF 6 Fail O 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Portable Fire Extingusihers Status Code Fail O 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Mechanical room Comments: Properly mount and support power strip to avoid hanging by wires. Description Location: Fire extinguishers Comments: Provide annual service to fire extinguishers, last recorded service in 2023 GENERATED ON 2/16/26, 7:33 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 2/16/26, 7:33 AM 6 OF 6