Loading...
HomeMy WebLinkAbout310 E 4TH ST0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/18/2026 03/25/2026 2026-00000341 $80.00 Customer #: 24912 JONES, JEREMY BOOTLEGGERS 310E4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 310 E 4TH ST - 2/17/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24912 02/18/2026 03/25/2026 2026-00000341 $80.00 Less Prepayment Total Due — > City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Bootleggers - 310 E 4th ST, BLDG 310 E 4th St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 02/17/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) 2tiQ12 -��+ Other Inspectors N/A Shift Station NIA NIA 425 E. 3rd Street Inspection Number 16334 Unit NIA SUMMARY OF INSPECTION 0 43 Passed codes NEXT STEPS 0 5 Failed codes 0 25 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 02/1812026 @ 07:39 $80 annual inspection fee BRAD BALDWIN - 02118/2026 @ 07:54 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 02118/2026 @ 07:54 Reinspection Date 03/11/2026 • Provide corrections to avoid progressive re -inspection fees beginning at $100. BeeriLiquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 02118/2026 © 07:55 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and 5200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Jeremy Jones CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 02/18/2026 GENERATED ON 2/18/26, 7:57 AM 1 OF 3 Electrical Safety Status Code Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Status rode Fail Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Portable Fire Extingusihers Status Code Fail Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Description Location: Kitchen fridge Comments: Remove fridge from plugged to extension cord. Appliance shall be plugged directly to wall outlet. Description Location: Kitchen exhaust hood Comments: Exhaust system cleaning 185 days past due as of 2118/26. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. Location: Kitchen hood suppression system Comments: Suppression system 174 days past due for inspection as of 2/18/26, contractor shall provide report with any deficiencies corrected to be uploaded to Compliance Engine. Description Location: All extinguishers Comments: Extinguishers past due for service, provide service to all required extinguishers. Location: Kitchen class K extinguisher Comments: Extinguisher shall be properly mounted on wall bracket, currently sitting on floor GENERATED ON 2/18/26, 7:57 AM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 2/18/26, 7:57 AM 3 OF 3