Loading...
HomeMy WebLinkAbout110 E 11TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/18/2026 03/25/2026 2026-00000336 $80.00 Customer #: 22278 EDO'S 110 EAST 11 TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 110 E 11TH ST - 02/16/2026 FOR BILLING INQUIRY (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22278 02/18/2026 03/25/2026 2026-00000336 $80.00 Less Prepayment Total Due —+ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. titc) 22218 Waterloo Fire Rescue Inspection Report Edo's - 110 E 11th ST, BLDG 110 E 11th St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 02/16/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 16650 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 41 Passed codes NEXT STEPS 9 Failed codes 0 25 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 02/17/2026 @ 13:07 • $80 annual inspection fee BRAD BALDWIN - 02/17/2026 @ 13:21 Christmas lighting approved for temporary use (90 days) BRAD BALDWIN - 02/17/2026 @ 13:29 Extinguishers due annually serviced January 2027 BRAD BALDWIN - 02/17/2026 @ 13:30 Inspector not given access to 2 offices near mechanical room BRAD BALDWIN - 02/17/2026 @ 13:47 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 03/12/2026 BRAD BALDWIN - 02/17/2026 @ 13:47 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 02/17/2026 @ 13:50 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. ""***Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 2/17/26, 1:52 PM 1 OF 7 Edin Sahinovic CHECKLISTS Means of Egress Status Code Fail Date: 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. BRAD BALDWIN 02/17/2026 Description Location: llth St exit Comments: Remove plywood from egress path immediately. Maintain dear path of egress at all times. GENERATED ON 2/17/26, 1:52 PM 2 OF 7 Additional Codes Status Code Fail Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 6103.2.1 - Portable containers. Portable LP -gas containers, as defined in NFPA 58, shall not be used in buildings except as specified in NFPA 58 and Sections 6103.2.1.1 through 6103.2.1.7. Emergency Equipment Status Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required Toad for a duration of not Tess than 90 minutes. peon Location: HVAC & electric permits for furnace Comments: Contractor (Low Dollar) shall obtain inspection of work completed. Permit obtained 11/13/25, no inspection on record. Location: Smoking room Comments: Remove LP heater from building. Description Location: storage room by kitchen Comments: Repair or replace exit sign/egress lights combo that failed to illuminate during test. GENERATED ON 2/17/26, 1:52 PM 3 OF 7 Electrical Safety Status Cede Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Water heater room Comments: Install missing outlet cover. Location: Mechanical room by bathrooms Comments: Remove obstructions to clear access to electric panel. 36" clear space in front of panel shall be maintained. GENERATED ON 2/17/26, 1:52 PM 4 OF 7 Fail Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: DJ Booth Comments: Remove power strip plugged to another power strip. Each individual strip shall plug directly to wall outlet. Location: Kitchen next to fridge Comments: Remove brown extension cord from permanent usage, appliances shall plug directly to wall outlet. GENERATED ON 2/17/26, 1:52 PM 5 OF 7 Portable Fire Extingusihers Status Cud? Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Storage room near kitchen Comments: Provide annual service to extinguishers, last tagged for service Feb 2025. GENERATED ON 2/17/26, 1:52 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number N/A Check Number Transaction Number N/A N/A GENERATED ON 2/17/26, 1:52 PM 7 OF 7