RENTAL FIRE INSPECTION - 227 ALLEN ST - 02/19/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION FEE 2ND
$150.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24688
02/24/2026
03/31/2026
2026-00000075
$150.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$150.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
W A\ }o Estate I ft) q I once,. 'slew( Ave.
Waterloo Fire Rescue
Inspection Report
Apt @ 227 Allen - 227 Allen, BLDG 223/225/227 Allen, Waterloo IA 50701
INSPECTION DETAILS
Inspection Date
02/19/2026
Lead Inspector
NATE BEUSELING
? k 'tutu ✓--'"'
Inspection Type
Rental Inspection REINSPECTION
Other Inspectors
N/A
425 E. 3rd Street
Inspection Number
15985-R4
Shift Station Unit
NIA NIA N/A
SUMMARY OF INSPECTION
0 o
Passed codes
NEXT STEPS
0 3
Resolved violations
0 5
Failed codes
Please direct questions about your Inspection to:
NATE BEUSELING
nate.beuseling@waterloo-ia.org
GENERAL NOTES
Reinspection Date
03/2112026
NATE BEUSELING - 02/19/2026 @ 11:44
AT reinspection non egress bedroom still being used as bedroom previous note expresses that ownership would communicate with tenants moving
forward that that room was not to be allowed, receptacle in bedroom has no cover on it, plumbing in kitchen sink leaking reinspection fee of 150.00
BRAD BALDWIN - 05/09/2025 @ 07:05
$100.00 no show fee for scheduled inspection on 3/27/25. $50.00 Re -inspection fee
BRAD BALDWIN - 05/09/2025 @ 07:05
Property Safety Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-464-5605
BRAD BALDWIN - 05/09/2025 @ 07:05
-Re-inspection date is as posted on the inspection report given, the rental unit's responsible person/5 shall reach out prior to set time of that re -
inspection. If all corrections are made before the scheduled inspection, you can call to set up an earlier re -inspection. Appropriate notices shall be given
to occupants of the units. Owner or owner's agent must be present during inspections. Failure to schedule a time on the date given or failure to keep the
inspection will result in a $100 fee. *****Re inspection fees may be assessed for re -inspections. Re -inspection fees start at $50, then $150, and $250 for all
subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspection.
BRAD BALDWIN - 05/09/2025 @ 07:05
Reliability notes: Room to opposite side of kitchen wall previously used as bedroom fails to provide proper egress shall not be used as bedroom or for
sleeping in its current state. First room inside unit entry door shall be used as bedroom/sleeping. Ownership shall notify all future tenants of restrictions.
BRAD BALDWIN - 05/09/2025 @ 07:05
Appropriate work requiring permits & inspections in the City Of Waterloo shall be obtained.
BRAD BALDWIN - 05/09/2025 @ 07:05
$100- failure to keep scheduled inspection on 5/8/25. $150- Reinspection fee.
SIGNATURES
Contact signature Inspector signature
GENERATED ON 2/19/26, 1:04 PM
1 OF 4
No signature
Report completed post inspection
Pregler Properties Date:
CHECKLISTS
NATE BEUSELING
02119/2026
GENERATED ON 2/19/26, 1:04 PM
2 OF 4
Reinspection
Stotus Code
Fail
Fail
Fail
Fail
Fail
1032.2 -Reliability.
Required exit accesses, exits and exit discharges shall be
continuously maintained free from obstructions or
impediments to full instant use in the case of fire or other
emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
907.2.11.2 - Groups R-2, R-3, R-4 and 1-1.
Single- or multiple -station smoke alarms shall be installed
and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2.In each room used for
sleeping purposes. 3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level.
R5 - Exterior Structure
Is the exterior of the structure maintained in good repair,
structurally sound and sanitary state? (IPMC 304)
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Description
Location: Bedroom
Comments: See notes for details.
Location: Room outlet
Comments: Outlet loose in wall shall be corrected. 604.3 Electrical
system hazards. Where it is found that the electrical system in a
structure constitutes a hazard to the occupants or the structure by
reason of inadequate service, improper fusing, insufficient receptacle
and lighting outlets, improper wiring or installation, deterioration or
damage, or for similar reasons, the code official shall require the
defects to be corrected to eliminate the hazard.
Additional comments: Outlet replaced with GFCI outlet but has no
cover shall be covered
Location: Basement
Comments: No smoke detector found. Detector in proper working
order shall be installed.
Location: Rear exterior steps
Comments: Stairway shall have handrail installed to proper code
standards. 307.1 General. Every exterior and interior flight of stairs
having more than four risers shall have a handrail on one side of the
stair and every open portion of a stair, landing, balcony, porch, deck,
ramp or other walking surface that is more than 30 inches (762 mm)
above the floor or grade below shall have guards.
Location: Kitchen sink drainage
Comments: Improper drainage ("s trap" & flexible piping not to code)
installation shall be corrected. Installation of waste/vent piping shall
be done by licensed plumber with permit and inspections obtained.
[P] 504.3 Plumbing system hazards. Where it is found that a plumbing
system in a structure constitutes a hazard to the occupants or the
structure by reason of inadequate service, inadequate venting, cross
connection, backsiphonage, improper installation, deterioration or
damage or for similar reasons, the code official shall require the
defects to be corrected to eliminate the hazard.
Additional comments: S trap replaced to P trap plumbing but was
found to be leaking at reinspection
GENERATED ON 2/19/26, 1:04 PM