HomeMy WebLinkAbout1016 MAYNARD AVECustomer #: 4428 BUZZ'S BAR 1016 MAYNARD WATERLOO, IA 50701 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/26/2026 04/02/2026 2026-00000353 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1016 MAYNARD AVE - 02/23/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING. DATE DUE DATE INVOICE # CHARGES 4428 02/26/2026 04/02/2026 2026-00000353 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Buzz's Bar - 1016 Maynard AVE, BLDG 1016 Maynard Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 02/23/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 16344 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 034 Passed codes NEXT STEPS 0 9 Failed codes 35 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 02/24/2026 @ 10:49 $80 annual inspection fee BRAD BALDWIN - 02124/2026 @ 12:58 Fire extinguishers due annually serviced in October 2026. BRAD BALDWIN - 02/25/2026 @ 15:33 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 03/19/2026 BRAD BALDWIN - 02125/2026 @ 15:33 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 0212512026 @ 15:34 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Kyle Weliver 2026 CHECKLISTS Date: BRAD BALDWIN 0212512026 GENERATED ON 2/25/26, 3:48 PM 1 OF 7 Additional Codes Status Code Fail 1010.2.1 - Unlatching. The unlatching of any door or leaf for egress shall require not require more than one operation motion in a single linear or rotational direction to release all latching and all locking devices. Exceptions: 1.Places of detention or restraint. 2.Where manually operated bolt locks are permitted by Section 1010.2.5. 3.Doors with automatic flush bolts as permitted by Section 1010.2.4, Item 3 4. 4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4, Item 4 5. Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Fail 310.2 - Prohibited areas. ri<`, Smoking shall be prohibited where conditions are such as to make smoking a hazard, and in spaces where flammable or combustible materials are stored or handled. Exception: In Group 1-2 occupancies, patients shall be permitted to smoke in designated patient care areas based on the clinical needs of the patient. Description Location: Main level door from basement Comments: Remove one of locking or latching devices from door. No more than a single motion is allowed to operate a door that is part of the egress path from a space. Location: South patio hanging heater Comments: Obtain electric permit and inspection for heater installed without permit. Location: South patio Comments: State of Iowa "Smokefree Air Act" has been attached. Windows in patio shall be in the opened position at all times during the event of a person smoking. GENERATED ON 2/25/26, 3:48 PM 2 OF 7 General Housekeeping Starks Code Fail 305.1 - Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Description Location: Basement mechanical area Comments: Remove all storage from room. Room also serves as part of 2nd exit from basement, clear path of egress to exit shall be maintained at all times. No storage in room. GENERATED ON 2/25/26, 3:48 PM 3OF 7 Electrical Safety Status Cod, - Fail 603.5.3 - Installation. ORelocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Fail CD 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Description Location: South patio Comments: Properly mount power strip to avoid hanging by wires. Location; South patio Comments: Remove extension cord running through window to avoid possible damage to cord. Extension cord plugged to Christmas lights approved for temporary usage (90 days). GENERATED ON 2/25/26, 3:48 PM 4 OF 7 Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Main exit vestibule Comments: Remove extension cord plugged to bug trap light. Relocate light to plug directly to permanent wall outlet. Location: South wall by popcorn maker Comments: Remove extension cord below TV, may replace with power strip with manual reset properly mounted to wall or supported for light duty electronics only. GENERATED ON 2/25/26, 3:48 PM 5 OF 7 Fire Resistant Construction Maintenance Status Coda Description Fail 704.1 - Maintaining protection. OWhere required when the building was originally constructed, Location: Basement above tables & chairs materials and systems used to protect joints and voids in the Comments: Replace missing ceiling tile. following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. GENERATED ON 2/25/26, 3:48 PM 6 OF 7 • Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 2/25/26, 3:48 PM 7 OF 7