Loading...
HomeMy WebLinkAbout1237/1239 ANSBOROUGH AVECustomer #: 9180 SUBWAY 1241 ANSBOROUGH AVE WATERLOO, IA 50701 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/02/2026 04/06/2026 2026-00000355 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1237/1239 ANSBOROUGH - 02/26/2026 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLINGDATE DUE DATE INVOICE # 9180 03/02/2026 04/06/2026 2026-00000355 CHARGES $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Subway - 1239 Ansborough AVE, BLDG 1239 Ansborough Ave, Waterloo IA 50701 1151 C.et � INSPECTION DETAILS Inspection Date 02/26/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other lnspectors NIA 425 E. 3rd Street Inspection Number 621 Shift Station Unit N/A NIA N/A SUMMARY OF INSPECTION 033 Passed codes NEXT STEPS 0 5 Failed codes 36 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 02/26/2026 @ 11:15 S80 annual inspection fee BRAD BALDWIN - 02126/2026 @ 15:23 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 03/27/2026 BRAD BALDWIN - 02/26/2026 @ 15:23 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and 5200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Rob Pruitt (2026) Date: BRAD BALDWIN 02/26/2026 CHECKLISTS GENERATED ON 2/26/26, 3:25 PM 1 OF 6 Additional Codes Status Code Fail 0 1010.2.1- Unlatching. The unlatching of any door or leaf for egress shall require not require more than one operation motion in a single linear or rotational direction to release all latching and all locking devices. Exceptions: 1.Places of detention or restraint. 2.Where manually operated bolt locks are permitted by Section 1010.2.5. 3.Doors with automatic flush bolts as permitted by Section 1010.2.4, Item 3 4. 4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4, Item 4 5. Description Location: Back exit Comments: Remove deadbolt hardware from door, exit door allowed nor more than a single motion to unlatch and unlock door. Owner stated hardware is currently inoperable so will remove. GENERATED ON 2/26/26, 3:25 PM 2 OF 6 Electrical Safety Status Code Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 min) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not Tess than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Near back exit Comments: Provide 36" clear space around and in front of electric panel. GENERATED ON 2/26/26, 3:25 PM 3 OF 6 Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multipiug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Above walk-in fridge Comments: Remove 3-way multi plug adapter from outlet. Location: Above walk-in fridge Comments: Remove extension cord plugged to TV. May replace with power strip with manual reset properly mounted for Tight duty electric only. Flexible cords shall not be installed in concealed area (above drop ceiling). GENERATED ON 2/26/26, 3:25 PM 4 OF 6 Portable Fire Extingusihers Status Code Fail O 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Extinguisher Comments: Provide annual service to extinguisher, last recorded service February 2025. GENERATED ON 2/26/26, 3:25 PM 5 OF 6 Statement of Fees FEE Invoice Date NIA Invoice Number NIA Inspection Fee $80.00 Date Paid Amount Paid Check Number NIA Transaction Number NIA GENERATED ON 2/26/26, 3:25 PM 6 OF 6