Loading...
HomeMy WebLinkAbout218 E 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/09/2026 04/13/2026 2026-00000366 $80.00 Customer #: 24926 SAVVY BEAN 218E 4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 218 E 4TH ST - 03/06/2026 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24926 03/09/2026 04/13/2026 2026-00000366 $80.00 Less Prepayment Total Due —+ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. #� 249Z(o Waterloo Fire Rescue Inspection Report Savvy Bean INSPECTION DETAILS Inspection Date 03/06/2026 •218E4thST,BLDG218E Lead lnspector BRAD BALDWIN 4th St, Waterloo IA 50703 Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 21002 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 46 0 6 ® 22 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/09/2026 @ 07:58 $80 annual inspection fee BRAD BALDWIN - 03/09/2026 @ 08:27 Christmas lighting approved for temporary usage (max 90 days). 2021 IFC: 603.8 BRAD BALDWIN - 03/09/2026 @ 08:28 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 04/08/2026 BRAD BALDWIN - 03/09/2026 @ 08:28 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection John Warren (Building) CHECKLISTS Date: BRAD BALDWIN 03109/2026 GENERATED ON 3/9/26, 8:32 AM 1 OF 4 Means of Egress Status Code Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. General Housekeeping Status Code Fail 305.1- Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Additional Codes Status Code Fail V 603.1- General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. Electrical Safety Status Failai� tt0 Code 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Front exit Comments: Remove obstructions to clear path of egress to exit. Description Location: Mechanical room Comments: Remove storage from room, maintain 36" clearance from fuel fired appliances. Description Location: Basement water softener Comments: Water softener shall plug directly to permanent outlet, currently plugged to light fixture plug. If adding new outlet, licensed electrical contractor shall obtain permit and inspection. Description Location: Basement Comments: Provide clear path of access to electric and gas services for fire fighters, maintain clear path and proper clearances at all times. GENERATED ON 3/9/26, 8:32 AM 2 OF 4 Fire Resistant Construction Maintenance Status Code Fail 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Etectronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Employee service room near bathroom hallway Comments: Replace missing ceiling tiles. Description Location: All fire extinguishers Comments: Provide annual service to extinguishers. Install properly mounted extinguisher in basement, extinguisher shall be located to not exceed 75 feet of travel to access. GENERATED ON 3/9/26, 8:32 AM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/9/26, 8:32 AM 4 OF 4