Loading...
HomeMy WebLinkAbout4045 HAMMOND AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/09/2026 04/13/2026 2026-00000361 $80.00 Customer #: 24925 PERKINS 4045 HAMMOND AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 4045 HAMMOND AVE - 02/27/2026 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24925 03/09/2026 04/13/2026 2026-00000361 $80.00 Less Prepayment Total Due —� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Perkins - 4045 Hammond AVE, BLDG 4045 Hammond Ave, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 02/27/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 1320 Shift Station Unit NIA N/A NIA SUMMARY OF INSPECTION 0 49 Passed codes NEXT STEPS O 19 Failed codes 10 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/0512026 @ 07:32 $80 annual inspection fee BRAD BALDWIN - 03/05/2026 @ 07:37 Fire extinguishers due annually serviced September 2026 BRAD BALDWIN - 03/0512026 @ 09:01 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 04/03/2026 BRAD BALDWIN - 03/05/2026 @ 09:01 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Annie Smith 2026 Date: BRAD BALDWIN 03/05/2026 CHECKLISTS GENERATED ON 3/5/26, 9:04 AM 1 OF 9 Means of Egress Status Code Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Additional Codes -"talus Code Fail Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 606.3.1- Ventilation system. The ventilation system in connection with hoods shall be operated at the required rate of air movement, and grease filters listed and labeled in accordance with UL 1046 shall be in place where equipment under a kitchen grease hood is used. Emergency Equipment Status Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: Kitchen (south) exit door Comments: Repair or replace door to allow door to open with less than 15 lbs of force. Door opened forcefully during inspection . Description Location: South kitchen exterior door frame Comments: Contractor (Allied Glass) shall obtain permit and inspection of door frame recently replaced without permit. Location: Main kitchen exhaust hood Comments: Close gaps in grease filters. Filters not in place cause more grease in ductwork and on cables for fire suppression Description Location: Men's & women's bathrooms Comments: Repair or replace egress emergency lights that failed to illuminate during test Location: Kitchen south exit Comments: Repair or replace exit signiegress lights combo that failed to illuminate during test. GENERATED ON 3/5/26, 9:04 AM 2 OF 9 General Housekeeping Status Cole Fail Fail Fail 304.3.1 - Spontaneous ignition. Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. Contents of such containers shall be removed and disposed of daily. 315.3.1 - Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches (457 mrn) below sprinkler head deflectors in sprinklered areas of buildings. Exceptions: 1.The 2-foot (610 mm) ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings. 2.The 18-inch (457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. 315.3.1- Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches (457 mrn) below sprinkler head deflectors in sprinklered areas of buildings. Exceptions: 1.The 2-foot (610 mm) ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings. 2.The 18-inch (457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. Fire Sprinkler System Status Code Fail 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. n Location: Kitchen Comments: Provide listed oily rag container, see attachment. Location: Kitchen dry storage Comments: Remove storage within 18 inches of ceiling. Location: Storage closet near bathrooms Comments: Remove storage within 18 inches of ceiling. Description Location: Storage closet by bathrooms Comments: Repair escutcheon loose to ceiling, escutcheon shall be tight to ceiling. GENERATED ON 3/5/26, 9:04 AM 3 OF 9 Fire Service Features =„aau< Code Fail Fail Fail 505.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not Tess than 4 inches (102 mm) high with a minimum stroke width of 112 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. 509.1- Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements fire protection systems shall be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Location: Hammond side of building Comments: Address number identification in contrast to the building shall be properly installed to face Hammond Blvd. Current address numbers of "4101" on kitchen exit door is old, invalid number shall be removed. Location: Sprinkler riser room Comments: Contact fire department (319) 291-4460 to update key in Knox Box to Riser Room. Location: Sprinkler riser room (North side of building) Comments: "Electrical Room" and "Sprinkler Riser Room' signage faded, shall be replaced. GENERATED ON 3/5/26, 9:04 AM 4 OF 9 Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Location: Sprinkler riser room (North side of building) Comments: Remove storage (shelving, racking) from room. GENERATED ON 3/5/26, 9:04 AM 5 OF 9 Electrical Safety Status Code Fail 603.2 - Abatement of unsafe conditions and electrical (0 hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: Electric panel by walk-in fridge Comments: Provide blank covers to openings in panel. GENERATED ON 3/5/26, 9:04 AM 6 OF 9 Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Commercial Cooking Hood Suppression System status Code Fail 606.3.3.1- Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: Parking lot (north) at flag pole Comments: Deteriorated box shall be replaced. Location: Kitchen coffee station Comments: Properly mount power strip to wall to avoid hanging by wires. Description Location: Hood exhaust suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 156 days past due per Compliance Engine. GENERATED ON 3/5/26, 9:04 AM 7 OF 9 Fire Resistant Construction Maintenance status codt. Fail 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. Portable Fire Extingusihers tt,G Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Kitchen Comments: Replace missing or loose ceiling tiles. Description Location: Main electric room (North side of building) Comments: Provide annual service to fire extinguisher, last recorded service October 2024 GENERATED ON 3/5/26, 9:04 AM 8 OF 9 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/5/26, 9:04 AM 9 OF 9