HomeMy WebLinkAbout225-229 E 4TH STuhi,s,Illitltgt»,'
y v
INVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
03/10/2026
04/14/2026
2026-00000369
$80.00
Customer #: 24517
THE NEXT LEVEL
229 E 4TH ST
WATERLOO, IA 50703
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION - 225-229 E 4TH ST - 03/09/2026
�Def tiara
FOR BILLING INQUIRY: (319)291-4323
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
24517
LNG DATE
03/10/2026
ATE
04/14/2026
2026-00000369
Less Prepayment
Total Due —>
City of Waterloo
$80.00
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
.0Qp 145n
Waterloo Fire Rescue
Inspection Report
The Next Level - 225 - 229 E 4th ST, BLDG 225 - 229 E 4th St, Waterloo IA 50703
INSPECTION DETAILS
Inspection Date
0310912026
Lead Inspector
JEREMIAH VANDYKE
Inspection Type
Annual Inspection (1Yr)
Other lnspectors
BRAD BALDWIN
Shift Station
NIA NIA
425 E. 3rd Street
Inspection Number
21021
Unit
NIA
SUMMARY OF INSPECTION
040 ®11 ®24
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to:
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE - 0310912026 @ 16:27
All fire extinguishers serviced by Pro Shield September 2025.
Reinspection Date
0410812026
JEREMIAH VANDYKE - 0310912026 @ 16:39
PERMIT INFO: • Any construction, electrical, plumbing, life safety, and HVAC requires proper permit and inspections. • All electrical work and repair must
be completed by a licensed electrical contractor with permits and inspections.
JEREMIAH VANDYKE - 0310912026 @ 16:40
311012025 S - (Semi -Annual) Kitchen Exhaust AKA SERVICES INC. Reviewed Compliant
JEREMIAH VANDYKE - 0310912026 @ 16:40
Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are
Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed
the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. "'*"Re inspection fees
may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.-
JEREMIAH VANDYKE - 0310912026 @ 16:40
Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615
JEREMIAH VANDYKE - 03/09/2026 @ 16:40
Inspection Fee = $80.00 (To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
1 OF 7
GENERATED ON 3/9/26, 4:55 PM
Lonnisha Robinson Date:
CHECKLISTS
Emergency Equipment
Status Code
Fail
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
General Housekeeping
Status Code
Fail
0
305.1- Clearance from ignition sources.
Clearance between ignition sources, such as luminaires,
heaters, flame -producing devices and combustible materials,
shall be maintained in an approved manner.
Fire Sprinkler System
Status Code
Fail
0
Fail
4.9 - Support of nonsprinkler system components
Sprinkler system components shall not be used to support
non -sprinkler system components unless expressly permitted
by NFPA 13.
5.2.1- Annual sprinkler system inspection
Sprinklers shall be inspected at least annually by licensed
contractor
Fire Service Features
Status Code
Fail
0
506.2 - Key box maintenance.
The operator of the building shall immediately notify the fire
code official and provide the new key where a lock is changed
or rekeyed. The key to such lock shall be secured in the key
box.
C71)
Descriptiorf
Location: Basement egress lights at bottom of steps and all the way
back.
Comments: 2 egress lights tested and failed. Need to repair or
replace.
Description
Location: Kitchen black curtains need to be removed. To close to
kitchen appliances.
Comments: Kitchen black curtains need to be removed. To close to
kitchen appliances.
Description
Location: Basement sprinkler pipes.
Comments: Wires, zip ties used for plumbing, need to be removed
from sprinkler pipes.
Location: Basement Sprinkler need inspected by licensed contractor.
Comments: Basement Sprinkler need inspected by licensed
contractor. Sprinkler report will need to be uploaded to compliance
engine by contractor.
Description
Location: Need master key for front and back door.
Comments: Need master key for front and back door. Call me to have
master keys put into Knox box.
GENERATED ON 3/9/26, 4:55 PM
2 OF 7
Additional Codes
Status
Fail
0
Fail
Code
5303.5.3 - Securing compressed gas containers, cylinders
and tanks.
Compressed gas containers, cylinders and tanks shall be
secured to prevent falling caused by contact, vibration or
seismic activity. Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object
with one or more restraints. 2.Securing containers, cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers, cylinders or tanks.
3. Nesting of compressed gas containers, cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public. Nesting shall be allowed
provided that the nested containers, cylinders or tanks, if
dislodged, do not obstruct the required means of egress.
4.Securing of compressed gas containers, cylinders and
tanks to or within a rack, framework, cabinet or similar
assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of
examination, filling, transport or servicing.
605.5.2.3 - Gas containers.
Fuel gas containers for portable outdoor gas -fired heating
appliances shall comply with Sections 605.5.2.3.1 through
605.5.2.3.4.
Description
Location: Basement tanks for pop machine.
Comments: Tanks need to be secured to wall via chain to prevent
falling over. Can not be chanined to movable racks.
Location: LP tank must be removed from basement.
Comments: LP tank must be removed from basement.
GENERATED ON 3/9/26, 4:55 PM
3 OF 7
Electrical Safety
Status Code
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Description
Location: Kitchen back storage area yellow wiring running through
wall.
Comments: Contact licesned electician to install correct.
GENERATED ON 3/9/26, 4:55 PM
4 OF 7
Fail
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Commercial Cooking Hood Suppression System
Status Code
Fail 904.13.5.2 - Extinguishing system service.
OAutomatic fire -extinguishing systems shall be serviced not
less frequently than every six months and after activation of
the system. Inspection shall be by qualified individuals, and a
certificate of inspection shall be forwarded to the fire code
official upon completion.
Location: Green extension cord running through ceiling tile plugged
into ceiling projector.
Comments: Need to remove green extension cord.
Description
Location: Fire suppression system is past due 369 days.
Comments: Need to contact fire suppression contractor to service
hood and upload report to compliance engine.
GENERATED ON 3/9/26, 4:55 PM
5 OF 7
Fire Resistant Construction Maintenance
Status Code
Fail
704.1- Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Description
Location: Ceiling behind bar.
Comments: Ceiling tile needs to be put back in place.
GENERATED ON 3/9/26, 4:55 PM
6 OF 7
Statement of Fees
FEE
Invoice Date Inspection Fee
NIA $80.00
Invoice Number
NIA
Date Paid Amount Paid
Check Number Transaction Number
NIA NIA
GENERATED ON 3/9/26, 4:55 PM
7 OF 7