Loading...
HomeMy WebLinkAbout225-229 E 4TH STuhi,s,Illitltgt»,' y v INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/10/2026 04/14/2026 2026-00000369 $80.00 Customer #: 24517 THE NEXT LEVEL 229 E 4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 225-229 E 4TH ST - 03/09/2026 �Def tiara FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 24517 LNG DATE 03/10/2026 ATE 04/14/2026 2026-00000369 Less Prepayment Total Due —> City of Waterloo $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of .0Qp 145n Waterloo Fire Rescue Inspection Report The Next Level - 225 - 229 E 4th ST, BLDG 225 - 229 E 4th St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 0310912026 Lead Inspector JEREMIAH VANDYKE Inspection Type Annual Inspection (1Yr) Other lnspectors BRAD BALDWIN Shift Station NIA NIA 425 E. 3rd Street Inspection Number 21021 Unit NIA SUMMARY OF INSPECTION 040 ®11 ®24 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 0310912026 @ 16:27 All fire extinguishers serviced by Pro Shield September 2025. Reinspection Date 0410812026 JEREMIAH VANDYKE - 0310912026 @ 16:39 PERMIT INFO: • Any construction, electrical, plumbing, life safety, and HVAC requires proper permit and inspections. • All electrical work and repair must be completed by a licensed electrical contractor with permits and inspections. JEREMIAH VANDYKE - 0310912026 @ 16:40 311012025 S - (Semi -Annual) Kitchen Exhaust AKA SERVICES INC. Reviewed Compliant JEREMIAH VANDYKE - 0310912026 @ 16:40 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. "'*"Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 0310912026 @ 16:40 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 03/09/2026 @ 16:40 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection 1 OF 7 GENERATED ON 3/9/26, 4:55 PM Lonnisha Robinson Date: CHECKLISTS Emergency Equipment Status Code Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. General Housekeeping Status Code Fail 0 305.1- Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Fire Sprinkler System Status Code Fail 0 Fail 4.9 - Support of nonsprinkler system components Sprinkler system components shall not be used to support non -sprinkler system components unless expressly permitted by NFPA 13. 5.2.1- Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor Fire Service Features Status Code Fail 0 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. C71) Descriptiorf Location: Basement egress lights at bottom of steps and all the way back. Comments: 2 egress lights tested and failed. Need to repair or replace. Description Location: Kitchen black curtains need to be removed. To close to kitchen appliances. Comments: Kitchen black curtains need to be removed. To close to kitchen appliances. Description Location: Basement sprinkler pipes. Comments: Wires, zip ties used for plumbing, need to be removed from sprinkler pipes. Location: Basement Sprinkler need inspected by licensed contractor. Comments: Basement Sprinkler need inspected by licensed contractor. Sprinkler report will need to be uploaded to compliance engine by contractor. Description Location: Need master key for front and back door. Comments: Need master key for front and back door. Call me to have master keys put into Knox box. GENERATED ON 3/9/26, 4:55 PM 2 OF 7 Additional Codes Status Fail 0 Fail Code 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 605.5.2.3 - Gas containers. Fuel gas containers for portable outdoor gas -fired heating appliances shall comply with Sections 605.5.2.3.1 through 605.5.2.3.4. Description Location: Basement tanks for pop machine. Comments: Tanks need to be secured to wall via chain to prevent falling over. Can not be chanined to movable racks. Location: LP tank must be removed from basement. Comments: LP tank must be removed from basement. GENERATED ON 3/9/26, 4:55 PM 3 OF 7 Electrical Safety Status Code Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: Kitchen back storage area yellow wiring running through wall. Comments: Contact licesned electician to install correct. GENERATED ON 3/9/26, 4:55 PM 4 OF 7 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Status Code Fail 904.13.5.2 - Extinguishing system service. OAutomatic fire -extinguishing systems shall be serviced not less frequently than every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Location: Green extension cord running through ceiling tile plugged into ceiling projector. Comments: Need to remove green extension cord. Description Location: Fire suppression system is past due 369 days. Comments: Need to contact fire suppression contractor to service hood and upload report to compliance engine. GENERATED ON 3/9/26, 4:55 PM 5 OF 7 Fire Resistant Construction Maintenance Status Code Fail 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Ceiling behind bar. Comments: Ceiling tile needs to be put back in place. GENERATED ON 3/9/26, 4:55 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/9/26, 4:55 PM 7 OF 7