COMMERCIAL FIRE INSPECTION - 999 HOME PLZ - 10/20/2025
FOR BILLING INQUIRY: (319)291-4323
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
DATE
UE DATE
5893
03/10/2026
04/14/2026
2026-00000370
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
EO 5$3,93
Waterloo Fire Rescue
Inspection Report
Wolfe Eye Clinic - 999 Home PLZ, BLDG 999 Home Plz - STE 1st Floor, Waterloo IA
50701-4822
INSPECTION DETAILS
Inspection Date
10/2012025
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
N/A
425 E. 3rd Street
Inspection Number
18392
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
049
Passed codes
NEXT STEPS
10 ®20
Failed codes NIA codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 10123/2025 @ 15:27
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN-1012112025 @ 08:14
$80 annual inspection fee
BRAD BALDWIN-1012112025 @ 08:40
Fire extinguishers due annually serviced in April 2026
Reinspection Date
11/24/2025
BRAD BALDWIN -10/23/2025 @ 15:27
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Victoria Lockhard (2025)
CHECKLISTS
Date: BRAD BALDWIN
2E3.
10/23/2025
GENERATED ON 10/23/25, 3:28 PM 1 OF 7
Emergency Equipment
S'.+.. s Code
Fail 1203.2.15 - Means of egress illumination.
OEmergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
Fail
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
Fail 1203.2.6 - Exit signs.
OEmergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
A4 f:( 0.,kkri.-
P-1
Description
Location: Near "Tech 1 Room"
Comments: Repair or replace egress lights and exit sign that failed to
illuminate during testing.
Location: Near managers office
Comments: Repair or replace egress lights and exit sign that failed to
illuminate during testing.
Location: Optical display area
Comments: Repair or replace egress lights (2) that failed to illuminate
during testing.
Location: North exit
Comments: Repair or replace exit sign that failed to illuminate during
testing.
Location: East exit
Comments: Repair or replace exit sign that failed to illuminate during
testing.
act. of v CvEer'
st. dcl-ef
n) 43)C )916 feLeV\
1/1/e> 0/v01cl 1444
GENERATED ON 10/23/25, 3:28 PM 2 OF 7
Electrical Safety
Status Code
Fail
Fail
603.9.4 - Prohibited areas.
Portable, electric space heaters shall not be operated within 3
feet (914 mm) of any combustible materials. Portable, electric
space heaters shall be operated only in locations for which
they are listed.
603.9.4 - Prohibited areas.
Portable, electric space heaters shall not be operated within 3
feet (914 mm) of any combustible materials. Portable, electric
space heaters shall be operated only in locations for which
they are listed.
Description
Location: Contact Tens lab
Comments: Remove space heate om power strip. Provide
documentation of proper listi . - of use in commercial space or
remove from building.
Location: Call center room
Comments: Provide documentation of proper listing of use in
commercial space or remove from building.
GENERATED ON 10/23/25, 128 PM
3 OF 7
Fail
603.9.4 - Prohibited areas.
Portable, electric space heaters shall not be operated within 3
feet (914 mm) of any combustible materials. Portable, electric
space heaters shall be operated only in locations for which
they are listed.
Location: Optical receptionist
Comments: Provide documentation of proper listing of use in
commercial space or remove from building.
GENERATED ON 10/23/25, 3:28 PM 4 OF 7
Fire Resistant Construction Maintenance
Status Code
Fail
704.1- Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.3 •' is in or between fire -resistance -rated
walls, floors or floo ceiling assemblies and roof or
roof/ceiling assembl s. 2.Joints in smoke barriers. 3.Voids at
the intersection of a h • izontal floor assembly and an exterior
curtain wall. 4.Voids at •e intersection of a horizontal smok
barrier and an exterior c ain wall. 5.Voids at the interse • n
of a nonfire-resistance-rat d floor assembly and an ex for
curtain wall. 6.Voids at the tersection of a vertical e
barrier and an exterior curta wall. 7.Voids at th - ntersection
of a vertical fire barrier and a onfire-resist. -rated roof
assembly. Unprotected joints : d voids d • of need to be
protected where such joints an, voids re not required to
be protected when the building as • iginally
constructed. Where the system d- -ign number is known, the
system shall be inspected to t i ing criteria and
manufacturer's installon in tructions.
Description
Location: "Lab"
Comments: Replace ssing ceiling tile in breakroom and storage
room
GENERATED ON 10/23/25, 3:28 PM
5 OF 7
Fail
704.1- Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or flooriceiling assemblies and roof or
rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire- -sistance-rated roof
assembly. Unprotected joints and void do not need to be
protected where such joints and voids re not required to
be protected when the building was origin Ily
constructed. Where the system design num er is known, the
system shall be inspected to the listing criter < and
manufacturer's installation instructions.
Location: South exit vestibule
Comments: Install loose ceiling tile back in grid
GENERATED ON 10/23/25, 3:28 PM