COMMERCIAL FIRE INSPECTION - 1415 E SAN MARNAN DR -
03/09/2026
FOR BILLING INQUIRY: (319)291-4323
ip
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
R#
BILLING DATE
DL
DATE
22675
03/10/2026
04/14/2026
2026-00000373
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Waterloo Fire Rescue
Inspection Report
Amigos 2 -1415 E San Marnan DR, BLDG 1415 E San Marnan Dr, Waterloo IA 50702
INSPECTION DETAILS
Inspection Date
0310912026
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
NIA
425 E. 3rd Street
Inspection Number
16702
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
041 012 024
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 0311012026 @ 10:00
$80 annual inspection fee
BRAD BALDWIN - 0311012026 @ 10:06
Corrected during 319126 inspection: Removed power strips daisy chained at hostess stand.
BRAD BALDWIN - 0311012026 @ 10:34
Fire extinguishers due annually serviced February 2027
BRAD BALDWIN - 03/1012026 @ 10:42
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
0410112026
BRAD BALDWIN - 0311012026 @ 10:42
• Provide corrections to avoid progressive re -inspection fees beginning at $100. BeerlLiquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 0311012026 @ 10:42
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
Nestor izquierdo
No signature
Report completed post inspection
BB
Date: BRAD BALDWIN 0311012026
GENERATED ON 3/10/26, 10:44 AN 1 OF 8
CHECKLISTS
Emergency Equipment
Status Code
Fail
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
General Housekeeping
Status Code
Fail
305.1- Clearance from ignition sources.
Clearance between ignition sources, such as luminaires,
heaters, flame -producing devices and combustible materials,
shall be maintained in an approved manner.
Fire Service Features
Status Code
Fail
0
505.1- Address identification.
New and existing buildings shall be provided with approved
address identification. The address identification shall be
legible and placed in a position that is visible from the street
or road fronting the property. Address identification
characters shall contrast with their background. Address
numbers shall be Arabic numbers or alphabetical letters.
Numbers shall not be spelled out. Each character shall be not
less than 4 inches (102 mm) high with a minimum stroke
width of 112 inch (12.7 mm). Where required by the fire code
official, address identification shall be provided in additional
approved locations to facilitate emergency response. Where
access is by means of a private road and the building cannot
be viewed from the public way, a monument, pole or other
sign or means shall be used to identify the structure. Address
identification shall be maintained.
Description
Location: Near ice machine
Comments: Repair or replace exit sign that failed to illuminate during
test.
Description
Location: Water heater
Comments: Remove storage (boxes) within 36" from water heater.
Description
Location: Front of building
Comments: Install address numbers in contrasting colors with the
building.
GENERATED ON 3/10/26, 10:44 AN
2 OF 8
Additional Codes
Status Code
Fail
Fail
5303.5.3 - Securing compressed gas containers, cylinders
and tanks.
Compressed gas containers, cylinders and tanks shall be
secured to prevent falling caused by contact, vibration or
seismic activity. Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object
with one or more restraints. 2.Securing containers, cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers, cylinders or tanks.
3. Nesting of compressed gas containers, cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public. Nesting shall be allowed
provided that the nested containers, cylinders or tanks, if
dislodged, do not obstruct the required means of egress.
4.Securing of compressed gas containers, cylinders and
tanks to or within a rack, framework, cabinet or similar
assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of
examination, filling, transport or servicing.
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
Description
Location: Kitchen
Comments: CO2 tanks shall be chained to avoid tip -over
Location: Near front exit
Comments: Provide documentation power strip is approved for use
in wet locations or remove.
GENERATED ON 3/10/26, 10:44 AM
3 OF 8
Fail
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
Location: Exterior neon lighting
Comments: All bare wiring shall be properly covered to avoid shock
hazard.
GENERATED ON 3/10/26, 10:44 AM 4 OF 8
Electrical Safety
Status Code
Fail
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Description
Location: South exterior overhang
Comments: Remove birds nest to expose how Tight fixture is plugged
in. Screw in plug adapters in this location are required to be GFCI
protected.
Location: West exterior
Comments: Provide proper exterior rated outlet covers that are
missing
GENERATED ON 3/10/26, 10:44 AM
5 OF 8
Fail
Fail
603.5.3 - Installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Location: Kitchen
Comments: Properly mount power strip to avoid hanging by wires
Location: Waiting area TV
Comments: Remove green extension cord from TV, would approve to
replace with properly mounted power strip with manual reset.
GENERATED ON 3/10/26, 10:44 AM
6 OF 8
Fail
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Commercial Cooking Hood Suppression System
Status Code
Fail
0
606.3.3 - Cleaning.
Hoods, grease -removal devices, fans, ducts and other
appurtenances shall be cleaned at intervals as required by
Sections 606.3.3.1 through 606.3.3.3.
Location: Dining area
Comments: Light cord shall be removed from above drop ceiling.
Cord may be ran below ceiling tiles.
Description
Location: Kitchen hood exhaust
Comments: Provide hood cleaning and report to be uploaded to
Compliance Engine with any deficiencies corrected. Currently 27
days past due 3110126
GENERATED ON 3/16/26, 10:44 AM 7 OF 8