Loading...
HomeMy WebLinkAbout2845 CROSSROADS BLVDINVOICE DATE DUE DATE INVOICE# TOTAL DUE 03/16/2026 04/20/2026 2026-00000377 $80.00 Customer #: 20755 PANCHERO'S MEXICAN GRILL 2475 CORAL COURT CORALVILLE, IA 52241 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2845 CROSSROADS BLVD - 03/13/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total ;Price;. INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 20755 BILLING DATE 03/16/2026 DUE DATE 04/20/2026 INVOICE # 2026-00000377 Less Prepayment Total Due --> City of Waterloo CIIARGES $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety clays of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue nspection Report Pancheros Mexican Grill - 2845 Crossroads BLVD, BLDG 2845 Crossroads Blvd, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 0311312026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 7530 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 41 Passed codes NEXT STEPS 08 025 Failed codes NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03113/2026 @ 14:56 • $80 annual inspection fee BRAD BALDWIN - 0311612026 @ 09:17 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 0311612026 @ 09:17 Reinspection Date 0411512026 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Josh Whiteman (2026) CHECKLISTS Emergency Equipment Status Cede Fail Date: BRAD BALDWIN 03/16/2026 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: Back (North) exit Comments: Repair or replace exit sign and egress lights combo that failed to illuminate during test. GENERATED ON 3/16/26, 9:19 AM 1 OF 6 General Housekeeping Status Code Fail O 304.3.1- Spontaneous ignition. Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. Contents of such containers shall be removed and disposed of daily. Electrical Safety Status Code Fail O 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Kitchen Comments: Provide listed container to dispose of oily rags, see attachment. Description Location: Electric panel Comments: Remove storage within 36" in front of electric panel (includes down to floor and out 36"), maintain clear path of access at all times. GENERATED ON 3/16/26, 9:19 AM 2 OF 6 Additional Codes Status Fail 0 Code 606.3.1- Ventilation system. The ventilation system in connection with hoods shall be operated at the required rate of air movement, and grease filters listed and labeled in accordance with UL 1046 shall be in place where equipment under a kitchen grease hood is used. Commercial Cooking Hood Suppression System Status Code Fail O Fail O 606.3.3.1- Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSIIIKECA C10. Description Location: Kitchen exhaust hood Comments: Replace missing hood filters Description Location: Hood suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 545 days past due. Missing suppression nozzle covers shall be replaced Location: Large hood exhaust Comments: Clean excess grease from cooking equipment, excess grease poses significant fire hazard. GENERATED ON 3/16/26, 9:19 AM 3 OF 6 Fire Resistant Construction Maintenance Status Code Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Above walk-in fridge Comments: Replace several missing ceiling tiles above walk-in GENERATED ON 3/16/26, 9:19 AM 4 OF 6 Portable Fire Extingusihers Status Code Fail O 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Comments: Provide annual service to all fire extinguishers, last recorded service completed March 2024. GENERATED ON 3/16/26, 9:19 AM 5 OF 6 Statement of Fees FEE Invoice Date NIA Invoice Number NIA Inspection Fee Date Paid Amount Paid $80.00 Check Number Transaction Number NIA NIA GENERATED ON 3/16/26, 9:19 AM 6 OF 6