Loading...
HomeMy WebLinkAbout106 BROOKERIDGE DRCustomer #: 4469 GOLDEN CHINA 106 BROOKERIDGE DR WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/16/2026 04/20/2026 2026-00000381 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 106 BROOKERIDGE DR - 03/11/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # '; 4469 BILLING DATE 03/16/2026 DUE DATE 04/20/2026 INVOICE # 2026-00000381 CHARGES $80.00 Less Prepayment Total Due — City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. A80 441p9 Waterloo Fire Rescue Inspection Report Golden China - 106 Brookeridge DR, BLDG 106 Brookeridge Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 0311112026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA Shift NIA 425 E. 3rd Street Inspection Number 16438 Station Unit NIA NIA SUMMARY OF INSPECTION 0 47 Passed codes NEXT STEPS 0 5 Failed codes 0 24 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/11/2026 @ 07:22 $80 annual inspection fee BRAD BALDWIN - 03111/2026 @ 07:24 Fire extinguishers due annually serviced in February 2027 BRAD BALDWIN - 03/1112026 @ 08:25 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 0410212026 BRAD BALDWIN - 03/1112026 @ 08:25 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection i<R Yeli Chiu Date: BRAD BALDWIN 03/11/2026 CHECKLISTS GENERATED ON 3/11/26, 8:37 AM 1 OF 4 Additional Codes Status code Fail Fail Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Commercial Cooking Hood Suppression System Status Code Fail 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSI/IKECA C10. Description Location: Water heater Comments: Contractor shall obtain permit and inspection of water heater (manufactured 2025) installed without permit. Location: Storage room behind hostess stand Comments: Secure compressed CO2 gas cylinders with chain to avoid tip over. Location: Cup machine behind counter Comments: Remove machine from power strip, plug directly to wall outlet Description Location: Large hood exhaust Comments: Clean excess grease noted on hood filters and suppression lines. GENERATED ON 3/11/26, 8:37 AM 2 OF 4 Portable Fire Extingusihers Status Code Fail O 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Near large hood exhaust Comments: Provide annual service to spare fire extinguisher or remove from building. GENERATED ON 3/11/26, 8:37 AM 3 OF 4 Statement of Fees FEE Invoice Date NIA Invoice Number NIA Inspection Fee Date Paid Amount Paid $80.00 Check Number Transaction Number NIA NIA GENERATED ON 3/11/26, 8:37 AM 4 OF 4