Loading...
HomeMy WebLinkAbout602 BROADWAY STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/16/2026 04/20/2026 2026-00000386 $80.00 Customer #: 24931 Emilio Castro Tortas Tacos 602 Broadway St WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 602 BROADWAY ST - 03/13/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 24931 BILLING DATE 03/16/2026 DUE DATE 04/20/2026 INVOICE # 2026-00000386 CI3ARGES $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. A • So 2L4951 Waterloo Fire Rescue Inspection Report Tortas Tacos - 602 Broadway ST, BLDG 602 Broadway St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 0311312026 Lead lnspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other lnspectors NIA 425 E. 3rd Street Inspection Number 21158 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 043 08 ®26 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/1312026 @ 14:03 • $80 annual inspection fee BRAD BALDWIN - 03/1312026 @ 14:07 Christmas lights approved for temporary usage (90 days). BRAD BALDWIN - 0311312026 @ 14:28 Fire extinguishers due annually service in May 2026 BRAD BALDWIN - 0311312026 @ 14:38 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 0311312026 @ 14:38 Reinspection Date 04/1012026 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Fermin Miranda Date: CHECKLISTS BRAD BALDWIN 03113/2026 GENERATED ON 3/13/26, 2:40 PM 1 OF 7 Additional Codes Scat <s Cod Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Description Location: Water heater Comments: Licensed plumbing contractor shall obtain permit and inspection for water heater installed not to code and without permit GENERATED ON 3/13/26, 2:40 PM 2 OF 7 Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: Basement Comments: Secure compressed gas cylinders with chain to avoid tip over. GENERATED ON 3/13/26, 2:40 PM 3 OF 7 Fail 606.2 - Where required. A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304,1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 7108, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type 1 hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mglm3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 7108. General Housekeeping Statue Code Fail 304.3.1 - Spontaneous ignition. Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. Contents of such containers shall be removed and disposed of daily. Comments: Cooktop must be under Type 1 hood with at least a 6" overlap and protected by fire suppression system. Move appliance under hood. Description Location: Oily Rags Comments: Provide listed container for oily rag disposal. See attachment GENERATED ON 3/13/26, 2:40 PM 4 OF 7 Electrical Safety Staint4_ Code Fail Fail 603.5 - Relocatable power taps and current taps.Muliiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Description Location: Ice machine, slushie machine, fridges Comments: Remove multi -plug adapters behind multiple appliances. Relocate appliances to individually plug directly to wall outlet or licensed electrical contractor shall add outlets by obtaining permits and inspections. Location: Between register counter and kitchen Comments: Remove green extension cord to security cameras. May replace with properly mounted power strip with manual reset for light duty electric only. GENERATED ON 3/13/26, 2:40 PM 5 OF 7 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Sti A+s3 Code Fail 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSIAKECA C10. Location: South kitchen door Comments: Remove brown extension cord wrapped around door closure hardware. Description Location: Kitchen exhaust hood Comments: Clean excess grease in hood, filters currently dripping grease. GENERATED ON 3/13/26, 2:40 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/13/26, 2:40 PM 7 OF 7