Loading...
HomeMy WebLinkAbout2040 KIMBALL AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/16/2026 04/20/2026 2026-00000380 $80.00 Customer #: 15150 CABIN COFFEE COMPANY 2040 KIMBALL AV WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2040 KIMBALL AVE - 03/11/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 15150 03/16/2026 04/20/2026 2026-00000380 $80.00 Less Prepayment Total Due --÷ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ,sgp 15150 Waterloo Fire Rescue Inspection Report Cabin Coffee Co. - 2040 Kimball AVE, BLDG 2040 Kimball Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 03/11/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 4600 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 33 Passed codes NEXT STEPS 7 Failed codes 37 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/11/2026 @ 15:40 $80 annual inspection fee BRAD BALDWIN - 03/12/2026 @ 07:34 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 04/1012026 BRAD BALDWIN - 03/1212026 @ 07:34 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Grant Rothweiler (2026) CHECKLISTS Date: BRAD BALDWIN 03/12/2026 GENERATED ON 3/12/26, 7:36 AM 1 OF 5 Emergency Equipment Status Code Fail O Fail O Fail O 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required Toad for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not Tess than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: Front exit Comments: Repair or replace exit sign, very dull during testing. Location: Exit near bathrooms Comments: Repair or replace exit sign and egress lights that failed to illuminate during test. Location: Exit near office Comments: Repair or replace exit sign and egress lights that failed to illuminate during test. Additional Codes Status Code Description Fail 603.1.1- Equipment and fixtureswiring. xO Electrical equipment and fixtures All electrical equipment, Location: Coffee grinder wiring, devices and appliances shall be tested; and listed by Comments: Remove appliance from power strip, shall plug directly to an approved agency and labeled; and installed, used and wall outlet. maintained in accordance with NFPA 70 and all instructions included as part of such listing. GENERATED ON 3/12/26, 7:36 AM 2 OF 5 Electrical Safety Status Code Description Fail 603.6 - Extension cords. OExtension cords and flexible cordsshall not be a substitute Location: Mechanical room for permanent wiring and shall be listed and labeled in Comments: Remove brown extension cord plugged to security accordance with UL 817. Extension cords and flexible camera. cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Below register Comments: Remove brown extension cord below counter GENERATED ON 3/12/26, 7:36 AM 3 OF 5 Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Fire extinguishers Comments: Provide annual service to all extinguishers, last recorded service completed in 2021 GENERATED ON 3/12/26, 7:36 AM 4 OF 5 ro FEE Statement of Fees Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/12/26, 7:36 AM 5 OF 5 7